Undertaking settings on the PC
Connecting the TORSIOTRONIC
the PC
 Make sure that the TORSIOTRONIC
off.
 Open the cover and turn it forwards to connect the
PC.
ATTENTION!
Malfunctions possible.
 Insert the micro USB connector to
stop into the socket in one
movement.
 Make sure that the connectors are
firmly seated.
 Insert the micro USB connector to stop into the
PC connection socket in one movement.
 Insert the USB connector into the PC's USB
connection.
 Start the SENSOMASTER software installed on
the PC.
 Switch on the TORSIOTRONIC
The connection between the TORSIOTRONIC
the PC is established automatically.
For information on operation of the
SENSOMASTER software, refer to the relevant
online help.
to
®
is switched
®
.
®
and
®
Resetting to factory settings
The TORSIOTRONIC
®
factory settings:
 Menu language German
 All menus shown
 Password protection switched off
 Automatic switching off after 15 min.
 Alert limit 80 %
On resetting to the factory settings, all of the
fastening data contained in the internal
TORSIOTRONIC
®
the fastening data up before resetting if
necessary.
Proceed as follows to reset the TORSIOTRONIC
to the factory settings:
 Connect the TORSIOTRONIC
 Start the SENSOMASTER software installed on
the PC.
 Switch on the TORSIOTRONIC
 Select the "Settings" tab on the PC.
 Select the "Parameters" tab.
 Click onto the "Factory settings" button.
 Confirm the prompt.
The TORSIOTRONIC
®
settings.
Alternatively, the TORSIOTRONIC
the factory settings in the "Configuration" menu
under "Delete all data". Proceed as follows to do
this:
 Open the configuration menu, see page 29.
 Select the "Delete all data" menu item.
 To reset the factory settings, confirm with OK.
 To cancel the process, press HOME.