9.1- BASIC MENU
DISPLAY
LAMP OUTPUT
←
CONTINUES
→
ELECTRIC LOCK
←
2s
→
AUTO CL
←
ACTIVE
→
PAUSE TIME
←
120s
→
PHOTO & PT
←
→
---
DELAY CLOSING M1
←
5 s
→
SLOWDOWN TIME
←
1 s
→
SENSITIVE EDGE
←
NC
→
9.2- ADVANCED MENU
DISPLAY
FORCE CONTROL M1
←
80%
→
- CONTINUOUS LAMP OUTPUT: Use an indicator with auto-flashing integrated circuit.
- INTERMITTENT LAMP OUTPUT: The control unit simulates flashing, use a fixed light
indicator or a normal light.
ELECTRIC LOCK (from 0s to 6s): Activation time of electric lock in seconds. At 0s the
electric lock is disabled.
- AUTO CL ACTIVE: Enables automatic closing at the end of the pause time.
- AUTO CL DEACTIVATE: Disables automatic closing.
This menu item is only available if automatic closing is enabled.
PAUSE TIME (from 0s to 120s): Pause time before automatic closing.
The intervention of a safety or stop command blocks the pause time.
This menu item is only available if automatic closing is enabled.
- PHOTO & PT ---: When the gate is stationary and in a fully opened position (or pedestrian
opening), the photocell is triggered and brings the pause time back to the value set in the
PAUSE TIME menu.
- PHOTO & PT 5s: When the gate is stationary and in a fully opened position (or pedestrian
opening position), the photocell is triggered and brings the pause time to 5s.
DELAY CLOSING M1 (from 0s to 15s): Defines the phase displacement between the two
leaves in closing in order to avoid their overlapping.
In closing, leaf M1 (hinged door) moves later than leaf M2 (beaten door) depending on the
set time. At 0s phase displacement is disabled.
SLOWDOWN TIME (from 0s to
the motors stop. Adjustable from 0s to
= 25% of the maximum operating time of M1 and M2.
%
At 0s deceleration is disabled.
It is recommended to enable deceleration with the control unit already installed.
- NC SENSITIVE EDGE: Mechanical type with normally closed contact.
- 8K2 SENSITIVE EDGE: With 8k2 ohm resistor.
Intervention by the sensitive edge during normal gate movement causes a short reversal
(duration: 1s) to free the obstacle.
This menu item is only available for systems with Electromechanical motors.
FORCE CONTROL M1 (from 40% to 100%): adjustment of the M1 motor force (hinged
door) to ensure the correct movement of the leaf.
WARNING! This parameter directly affects the impact force. After installation,
check that the set value complies with current safety regulations (*). If necessary,
install anti-crush safety devices (**).
NOTE: A change to this parameter will require reinstallation of the control unit.
DESCRIPTION
s): Deceleration time (opening and closing) before
%
s.
%
DESCRIPTION
9