FORCE CONTROL M2
←
80%
→
SENSITIVITY M1
←
75%
SENSITIVITY M2
←
75%
SENS SLODOW M1
←
30%
SENS SLODOW M2
←
30%
M1 OPERATING TIME
←
60 s
M2 OPERATING TIME
←
60 s
DELAY OPENING M2
←
2 s
PARTIAL OPENING
←
50%
(*) In the European Union apply EN 12453 for force limits and EN 12445 for the measuring method.
(**) Impact forces can be reduced by using safety edges.
This menu item is only available for systems with Electromechanical motors.
FORCE CONTROL M2 (from 40% to 100%): adjustment of the M2 motor force (beaten
door) to ensure the correct movement of the leaf.
WARNING! This parameter directly affects the impact force. After installation,
check that the set value complies with current safety regulations (*). If necessary,
install anti-crush safety devices (**).
NB: A change to this parameter will require reinstallation of the control unit.
This menu item is only available for systems with Electromechanical motors.
SENSIVITY M1 (from 0% to 100%): M1 motor obstacle sensitivity adjustment. The higher
the value, the greater the sensitivity when detecting an obstacle.
→
WARNING! This parameter directly affects the impact force. After installation,
check that the set value complies with current safety regulations (*). If necessary,
install anti-crush safety devices (**).
This menu item is only available for systems with Electromechanical motors.
SENSIVITY M2 (from 0% to 100%): M2 motor obstacle sensitivity adjustment. The higher
the value, the greater the sensitivity when detecting an obstacle.
→
WARNING! This parameter directly affects the impact force. After installation,
check that the set value complies with current safety regulations (*). If necessary,
install anti-crush safety devices (**).
This menu items only available for version 1.3.6 or later.
SENSIVITY IN SLOWDOWN TIME M1 (from 0% to 100%) M1 motor obstacle sensitivity
adjustment. The higher the value, the greater the sensitivity when detecting an obstacle.
→
WARNING! This parameter directly affects the impact force. After installation,
check that the set value complies with current safety regulations (*). If necessary,
install anti-crush safety devices (**).
This menu items only available for version 1.3.6 or later.
SENSIVITY IN SLOWDOWN TIME M2 (from 0% to 100%) M2 motor obstacle sensitivity
adjustment. The higher the value, the greater the sensitivity when detecting an obstacle.
→
WARNING! This parameter directly affects the impact force. After installation,
check that the set value complies with current safety regulations (*). If necessary,
install anti-crush safety devices (**).
This menu item is only available for systems with hydraulic motors.
M1 OPERATING TIME (from 0s to 60s): manual adjustment of operating time taken by
the M1 motor to perform a complete opening/closing manoeuvre.
→
NOTE: For systems with electromechanical motors, the operating time is auto-adjusted
during the installation phase and shown as additional information in the INFO menu.
This menu item is only available for systems with hydraulic motors.
M2 OPERATING TIME (from 0s to 60s): manual adjustment of operating time taken by
the M2 motor to perform a complete opening/closing manoeuvre.
→
NOTE: For systems with electromechanical motors, the operating time is auto-adjusted
during the installation phase and shown as additional information in the INFO menu.
DELAY OPENING M2 (from 0s to 15s): defines the phase displacement between the two
leaves in opening in order to avoid their overlapping.
→
In opening, leaf M2 moves later than leaf M1 depending on the set time. At 0s phase
displacement is disabled.
PEDESTRIAN OPENING (from 25 % to 100%): pedestrian opening is a movement that
can only be activated when the gate is completely closed; it enables only the opening of
→
the M1 leaf (hinged) according to the set percentage.