3. To avoid the cable and cord being damaged by sharp edges, the cable and
cord must be passed through a bushing (located at the bottom of Control Board)
before terminal board. The bushing must be used and must not be removed.
Terminals on the Outdoor Unit
Colour of wires (Connecting cables)
Terminals on the Indoor Unit
(Power Supply Cord)
Terminals on the isolating
devices from power supply
(Disconnecting means)
Power Supply 1
RCCB/ELCB
*1
Power Supply Cord
Terminal screw
M4
M5
*1 - Earth wire must be longer than other cables for safety reasons
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
No loose strand
when insert
Conductor
fully insert
ACCEPT
CONNECTING REQUIREMENT
For Indoor Unit WH-SDC0309K3E5 with WH-UDZ03KE5*, WH-UDZ05KE5*,
WH-UDZ07KE5*, WH-UDZ09KE5*
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and can be
connected to current supply network.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-3 and can be
connected to current supply network.
For Indoor Unit WH-SDC0309K6E5 with WH-UDZ03KE5*, WH-UDZ05KE5*,
WH-UDZ07KE5*, WH-UDZ09KE5*
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and can be
connected to current supply network.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-12.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-11 and
shall be connected to suitable supply network, with the following maximum
permissible system impedance Z
liaise with supply authority to ensure that the Power Supply 2 is connected only
to a supply of that impedance or less.
For Indoor Unit WH-SXC09K3E5 with WH-UXZ09KE5*
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-12 provided
that the short circuit power Ssc is greater than or equal to 4450kW at the intertace
point between the user's supply and the public system. It is the responsibility
of the installer or user of the equipment to ensure, by consultation with the
distribution network operator if necessary, that the equipment is connected
only to a supply with a short circuit power Ssc greater than or equal to 4450kW.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-3 and can be
connected to current supply network.
For Indoor Unit WH-SXC09K6E5, WH-SXC12K6E5 with WH-UXZ09KE5*,
WH-UXZ12KE5*
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-12 provided
that the short circuit power Ssc is greater than or equal to 4450kW at the intertace
point between the user's supply and the public system. It is the responsibility
of the installer or user of the equipment to ensure, by consultation with the
distribution network operator if necessary, that the equipment is connected
only to a supply with a short circuit power Ssc greater than or equal to 4450kW.
10
1
L
N
L
N
1
1
1
L
N
L
N
1
1
Power Supply 2
Terminal Board
*1
Holder
(Clamper)
Connecting Cable
Tightening torque cN•m {kgf•cm}
157~196 {16~20}
196~245 {20~25}
Indoor/outdoor
connecting
terminal board
5mm or more
(gap between wires)
Conductor
Conductor not
over insert
fully insert
PROHIBITED
PROHIBITED
= 0.123 ohm ( ) at the interface. Please
max
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-12.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-11 and
shall be connected to suitable supply network, with the following maximum
permissible system impedance Z
2
3
liaise with supply authority to ensure that the Power Supply 2 is connected only
to a supply of that impedance or less.
2
3
INSTALLATION OF REMOTE
6
Indoor Unit/
CONTROLLER AS ROOM
Outdoor Unit
connection
THERMOSTAT
• Remote Controller 3 mounted to the Indoor Unit can be moved to the room
and serve as Room Thermostat.
Installation Location
• Install at the height of 1 to 1.5 m from the fl oor (Location where average room
temperature can be detected).
• Install vertically against the wall.
• Avoid the following locations for installation.
1. By the window, etc. exposed to direct sunlight or direct air.
2. In the shadow or backside of objects deviated from the room airfl ow.
3. Location where condensation occurs (The Remote Controller is not
moisture proof or drip proof.)
4. Location near heat source.
5. Uneven surface.
• Keep distance of 1 m or more from the TV, radio and PC. (Cause of fuzzy
image or noise)
Remote Controller Wiring
Indoor Unit
• Remote Controller cable shall be (2 x min 0.3 mm²), of double insulation PVC-
sheathed or rubber sheathed cable. Total cable length shall be 50 m or less.
• Be careful not to connect cables to other terminals of Indoor Unit (e.g. power
source wiring terminal). Malfunction may occur.
• Do not bundle together with the power source wiring or store in the same metal
tube. Operation error may occur.
Remove The Remote Controller From Indoor Unit
1. Remove both Left Decoration Panel g and Right Decoration Panel h from
Front Plate 1 with gently push the panels from back.
2. Remove the 4 screws and take out the holder with Remote Controller 3.
= 0.123 ohm ( ) at the interface. Please
max
Remote Controller wiring
(fi eld supply)
• No polarity
Terminal for Remote Controller wiring
Gently push
from rear
Remove 4 screws
Remote Controller
1
2