Copper Tube
Nut
Clean the Inlet Screens
Disconnect the power and turn off the water supply.
Unthread the plastic nuts from the hot and cold inlets.
Remove the copper tubes. The O-ring and screen may be attached to the end of the tube.
If the screen remains in the check valve, use a small flat-blade screwdriver to gently pull the check
valve from the valve inlets.
Remove the screens from the copper tubes or check valves.
Clean the screens to remove any dirt or debris.
Rinse or replace the check valves and screens.
Reassemble the inlet connections.
Troubleshooting
WARNING: Risk of electric shock. Disconnect power before servicing.
CAUTION: Risk of personal injury. The valve may contain hot water; be careful when draining
any residual water.
NOTICE: Any valve maintenance should be performed by a Kohler Co. Authorized Service
Representative (ASR).
NOTICE: Turn off the water supply to the valve before performing any maintenance.
NOTE: For service parts information, visit your product page at kohler.com/serviceparts.
This troubleshooting guide is for general aid only. For service and installation issues or concerns, call
1-800-4KOHLER.
1145587-5-C
Check Valve
Screen
O-Ring
Seal
4
Boot
Split
Boot
Kohler Co.