Descargar Imprimir esta página

Angelo Po 04WVT1IV Manual De Uso E Instalación página 24

Plancha de inducción en vitrocerámica

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Main Parts
A)Hob: in ceramic material.
B)Cooking zone: consists of an induction module
which transmits heat to the ceramic hob.
C)Control knob: Turns the corresponding cooking
zone on and off and regulates its level.
D)Failure light: comes on to warn that the correspond-
ing cooking zone is malfunctioning.
E)Mains light: comes on to indicate that the corre-
sponding cooking zone is switched on.
F) Door: for accessing the inside of the appliance
Description
Mains voltage tolerance
Frequency
Minimum cookware bottom diameter
Maximum diameter of the bottom of the pot.
Room temperature :
Storage
Operation
Room relative humidity:
Storage
Operation
IT
IT
Power available for each cooking zone:
Minimum
GB
GB
Maximum
For all other data, see tables and "Connection Diagram" at back of manual.
DE
DE
FR
FR
Although the appliance is complete with all safety
devices, during installation and connection addi-
ES
ES
tional devices must be added if necessary to com-
ply with the relevant legal requirements.
A)Pan recognition device: cuts out the cooking
zone if no pan is peasant or if the pan is empty.
B)Temperature sensor: cuts out the cooking zone if
the temperature is too high. Once the problem has
been resolved and the temperature has returned to
normal, operation is automatically restored.
C)Cooling fan: reduces the temperature of compo-
nents if they overheat.
English
TECHNICAL DATA
SAFETY DEVICES
B
D
C
E
F
04WVT1IV
04WVT2IV
-20 ÷ +70°C / 0 ÷ 160°F
+5 ÷ +40°C / +40 ÷ 110°F
1 kW
1 kW
5 kW
7 kW
Important
The cooling fan operates even if the control
knob is turned off ("0" setting) until the tem-
perature returns to normal levels.
Caution - warning
Make a daily check that the safety devices are
properly installed and in good working order.
Note: All safety devices are located inside the in-
duction module and are therefore not visible from
the outside.
- 4 -
A
D
E
C
08WVT1IV
+6V / -10V
50 / 60 Hz
~ 12 cm
~ 30 cm
10 - 90%
30 - 90%
1 kW
5 kW
D
E
C
D
C
E
A
F
B
IDM-39613200200.tif
08WVT2IV
1 kW
7 kW

Publicidad

loading

Este manual también es adecuado para:

04wvt2iv08wvt1iv08wvt2iv