36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
RISK OF ELECTRIC SHOCK, FRAME GROUNDED
TO NEUTRAL OF APPLIANCE THROUGH
A LINK. Grounding through the netural
conductor is prohibited for new banch-circuit
installations(1996 nec); mobile homes; and
recreational vehicles, or in an area where local
codes prohibit grounding through the neutral
conductor is prohibited.
For installations where grounding through the
neutral conductor is prohibited.
1.
Use grounding lead to A26377901 ground unit.
2. Connect neutral terminal or lead to brach-
circuit neutral in usual manner. To connect
appliance with a 4 wire connection do not use
grounding lead to A26377901.
IMPORTANT: Consult your installation instructions
for "electrical connection procedures".
Use copper or alluminium wire for connection to
permanent wiring.
When power supply cord kit is used to connect
range to the power supply, use only cord kits rated
120/240 volts minimum, and marked for use with
ranges. Refer to installation instructions for proper
cord kit ampere rating. Risk of fire or elctrical
shock may be incurred if an incorrect size range
cord kit is used, the installation instructions are
not followed, or the strain relief (Strain relief not
supplied with unit) bracket is discarded.
All screw & nut connection must be tight.
3.1
4 Wire Power Cord Installation
1.
Remove two screws at the top of the Terminal
Block cover using Phillips head screwdriver.
2. Follow the manufacturer's installation
instructions supplied with the strain relief (Strain
relief not supplied with unit) and install it.
3. Attach conduit cable to terminal block in
accordance to the corresponding color order
(See figure 7) by removing the intended screw,
slipping the wire onto screw and screwing it
back into position.
4 WIRE
GREEN
WHITE
BLACK
RED
Figure 7: 4 Wire Power Supply Cord Connection
4. Reinstall the terminal block cover.
3.2
4 Wire Power Cord Installation (for
non-terminated ends)
Figure 8: Terminal Adapters
1.
Remove two screws at the top of the Terminal
Block cover using Phillips head screwdriver.
2. Follow the manufacturer's installation
instructions supplied with the strain relief (Strain
relief not supplied with unit) and install it.
3. Attach Terminal adapters (4X) supplied in the
kit to terminal block by removing the intended
screw, slipping the adapter onto screw and
screwing it back into position. Attach all 4
adapters. Refer the figure 8.
4. Loosen the second screw on the adapter using
flat head screw driver, Push the wire through the
opening underneath the screw and then tighten
the screw back. Give a slight pull to make sure
the wire is secured.
10
GREEN
WHITE
BLACK
RED
Terminal
Adapters