36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
Always provide an adequate gas supply.
This appliance is shipped from the factory for
use with natural gas. Use this kit to convert the
appliance for use with propane gas, if necessary.
Comply with the following:
•
Ensure that the range is converted for use with
the appropriate gas before using it.
•
This appliance is designed to operate at a
pressure of 10" of water column when used
with propane gas.
When checking if the regulator is working properly,
the inlet pressure must be at least 1" greater than
the operating (manifold) pressure above. When
con-verting for propane gas use, the pressure
supplied to the regulator must be between 11" and
13" of the water column.
The pressure regulator located in the inlet of the
range manifold must remain in the supply line.
Use a flexible metal appliance connector or rigid
pipe to connect the range to the gas supply. The
connector should have an inside diameter of 1/2"
and be 5 ft (1.5 m) or less in length.
(Exception: Maximum connector length in Massa-
chusetts installations is 3 ft (0.9 m). In Canada,
the connector must be single-wall metal and not
longer than 6 ft (1.8 m).
Save the nozzles removed from the appliance for
future use.
Setting the pressure regulator for Propane Gas
1.
Unscrew regulator cap.
2. Unscrew the plastic regulator stem from the
regulator cap. Configuration "A" is for Natural
Gas.
3. Invert the plastic regulator stem to achieve the
configuration "B" for Propane Gas and screw it
in tightly.
4. Screw the regulator stem and cap into place.
NOTE: When converting for Propane Gas use,
the pressure supplied to the regulator must be
between 11" and 13" of the water column.
Replacing the cooktop burner nozzles
1.
Remove the cooktop grates.
2. Remove the burner cap, the burner head and the
burner cup (for Dual burner) from the burner
base. Refer to figure 14.
3. Using the appropriate size socket, remove the
nozzle.
4. Install the LP gas nozzles supplied in the kit. Do
not overtighten. Refer to below table for nozzle
part numbers.
NOTE: Dual burners (Burner 4) use two nozzles,
one at the center and other at its periphery.
NOTE: Save the nozzles removed from the
appliance for future use.
Burner and nozzles placements
2
4
LP gas nozzles table (Pressure in W.C.P.: 10")
Burner number
Center nozzle
number
Peripheral nozzle
number
Natural gas nozzles table (Pressure in W.C.P.: 4")
Burner number
Center nozzle
number
Peripheral nozzle
number
13
3
1
4
3
1
2
3
66
81
118
-
-
-
1
2
3
107
146
195
-
-
-
4
109
40
4
198
55