36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
3 & 4 - Wire electrical wall Receptacle types &
recommended mounting orientation on wall
G G
Y Y
X X
W
W
W
W
X X
Y Y
When only 4-wire, single phase, 240 volt, 60
Hz, AC-only electrical supply is available, this
appliance requires minimum 40 amp circuit
protection fused on both sides of the line.
A time-delay circuit breaker or fuse is
recommended.
Be sure the wall receptacle is within reach of the
appliance's final installed location.
Do not pinch the power supply cord between the
range and the wall.
Recommended Wall Outlet Installation
Locations
Suggested location of the wall outlet is shown in
Figure 4. The outlet may also be located in the
lower left corner of the adjacent right cabinet, as
shown in Figure 5.
Center
Line of
Range
L
W A L
Figure 4: Outlet Location
Required for new and
remodeled installations
4-Wire Wall
receptacle (14-50R)
Allowed for
existing installations
3-Wire Wall
receptacle (10-50R)
13"
(33.02 cm)
5" Max.
(1
2.7
cm Max.)
Locate Electrical Hook-up
Inside Shaded Area
Center
Line of
Range
Figure 5: Adjacent Cabinet Outlet Location
3
Power Supply Cord
Electrical Shock Hazard –Do not attempt to
install the appliance directly to a junction box.
If the wall outlet is not sufficient to support
the requirements of this appliance, it is the
responsibility of the consumer to have the
appropriate outlet installed by an electrician.
Improper installation and electrical connections
can result in electric shock, damage to the
appliance, personal injury, fire, or death.
NOTE: Power supply cord is not supplied with the
product, customer needs to buy it separately.
Figure 6: Power Supply Cord
Appliance Rating*
120/240 Volts
120/208 Volts
1-10 kW
0-7.6 kW
8.8-16.5 kW
7.8-12.5 kW
16.6-22.5 kW
12.6-18.5 kW
* The NEC calculated load is less than the total
connected load listed on the serial plate.
9
8"
(20.3 cm)
12"
(30.5 cm)
Power Supply
Rating
Amps
30
40 or 50
50