15.WARNING BUZZERS AND PROCEDURES TO FOLLOW
This tool sounds warning buzzers for the conditions described below. If the buzzer sounds, follow
procedures according to the conditions described below.
• If the conditions described below occur, set the Main switch (Fig.1.
the Battery pack (Fig.1.5) before following procedures.
• Do not touch the tying or rotating parts at the tip when setting the Main switch at "ON" under
any circumstances.
<Buzzer types and procedures to follow>
Buzzer types
Once (Pi, pi, pi...)
Twice (Pipi, pipi, pipi...)
Three times
(Pipipi, pipipi, pipipi...)
Five times
(Piipiipiipiipii,
Piipiipiipiipii...)
Continuous high pitched
beep (Piii...)
Continuous high & low
pitched chime
(Pii poh Pii poh...)
Single-short beep
(Popi)
WARNING
Possible cause
Wire is jammed in the Hook
g
(Fig.1.
)
Low battery
Battery pack is not fully inserted
Tiewire is used up
Tiewire is jammed
Dust the sensor in Magazine.
Motor is hot
Curl guide (Fig.1.0) is open.
Internal structure; defect in internal
driving mechanism
Torque dial is not properly
positioned.
Check whether the wire or anything else
is caught in the Hook.
Charge the Battery pack.
Insert the Battery pack properly.
Replace with a new Tiewire.
Open the Magazine cover (Fig.12.
and fix the jammed wire.
Dust the sides of sensors and lenses
with water or cotton bud gently.
Let the tool rest and cool down.
Confirm supported rebar diameters.
Immediately discontinue operation and
set the Main switch (Fig.6.f) at "OFF"
and remove the Battery pack (Fig.6.
before consulting. Then contact the
dealer where the tool was purchased or
MAX CO., LTD. authorized distributors.
Move the tension adjustment dial to the
appropriate position. Sounding
continuously indicates a failure.
22
) at "OFF" and remove
f
Procedures to follow
r
)
5
)