4.3
Mounting the product
CAUTION
FloCo-Top-1K / 223
The maximum ambient temperature must not be exceeded, see
table 4, page 17. This means that you must not mount the Flo-
Co-Top-1 on top of or next to a non-insulated boiler part, above
opening dampers at furnaces or to the flue gas pipe.
The float housing must point vertically to the top.
Mount FloCo-Top-1 to the boiler casing using the enclosed
bracket 4 self-tapping screws. Drill the fixing holes with a
Ø 3 mm drill.
You can use the bracket as a template when screwing in the
screws ( points upwards).
Damage to the pump or to FloCo-Top-1 if the flow and return
lines are not properly connected.
Do not confuse the supply and return connections, not even
during commissioning for a short period of time.
– English –
Mounting and commissioning
21