Fig. 16: Vent hose
1.
Open the vent connection with a spanner size 19 until the O ring
is in contact with the plane surface of the hood.
2.
Push the vent hose onto the vent nipple and route it along the
suction line back to the tank.
3.
Fixate the vent hose with cable ties.
4.
Mount the other end of the vent hose to the vent line or the re-
turn connection of the withdrawal fitting of the tank to avoid
clogging.
5.
Use the hose connection piece shipped with the unit for connec-
tion to the return connection of the withdrawal fitting.
Customer satisfaction is our prime objective. Please get in touch with
us if you have any questions, suggestions or problems regarding
your product.
The addresses of our worldwide representatives can be found on the
Internet at www.afriso.de.