Descargar Imprimir esta página

SolaX Power X1-EVC-7.2K Manual De Instalación página 57

Ocultar thumbs Ver también para X1-EVC-7.2K:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
Home Scene:
• Communication with Inverter
* If the system has zero injection requirement, the EV-Charger must communicate with the inverter.
** When communicating with the inverter, it is recommended to use a two-core cable as the communication
cable since it is more waterproof. If users use eight-core cable as the communication cable, the white inverter
connector must be used to allow the system to work normally.
OCPP Scene:
• Installation and wiring steps
1
Inverter
PV array
Optional:
Inverter
connector
(white) **
AC
distribution
box
M4
AC
distribution
CT/
box
Meter
RCBO
Home
loads
Electricity
meter,
bidirectional
EV-Charger
RCBO
Meter
Grid
Electricity
meter,
bidirectional
EV-Charger
Grid
OCPP1.6
53

Publicidad

loading