Descargar Imprimir esta página

Pool Technologie Dosipool Ampero Instrucciones De Uso página 32

Dosador de cloro por controlo amperométrico + regulador de ph

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
2.10. Safety
2.10.1. Alarms
All alarms are activated by default.
Any alarm that is activated is immediately displayed on the screen.
To cancel an alarm: press the OK button.
As long as a detected fault remains, the corresponding alarm or warning is maintained, and the corresponding message
reappears a few moments after the acknowledgement.
IMMEDIATE AUTOMATIC
MESSAGE
DISPLAYED/FAULT
Amperometric
DETECTED
Info
pH calibration
Alarm
Empty pH container
Alarm
Empty CL container
Info
Cl gel
Alarm
Cl calibration
Alarm
Flow
STOP
pH
regulation
regulation
No
No
No
Yes
Yes
No
No
No
Yes
No
Yes
Yes
POSSIBLE CAUSE
pH probe incorrectly
calibrated
pH corrector container
empty
Empty chlorine container
Electrolyte gel of the
amperometric probe
absent or expired
Non-memorised
electrolytic gel
refill/change
Unadjusted free chlorine
rate measurement
Insufficient water flow
CHECKS AND
REMEDIES
Calibrate the pH
probe.
Replace the pH corrector
container.
Replace the chlorine
container.
Fill up/change the
electrolyte gel
Memorise the last
refill/change of
electrolyte gel.
Carry out an adjustment
of the free chlorine rate
measurement.
Check that:
- the flow sensor is
properly connected to
the electronics unit.
- the flow sensor is
activated (see sensor
settings).
- the valves on the
filtration circuit are
open.
- the filter pump is
working properly.
- the filtration circuit is not
blocked.
-
there is enough water in
the pool.
OPTION TO
DISABLE VIA
Settings -
MENU
Alarms
Yes
Yes
activated
Yes
activated
Yes
Yes
No
14

Publicidad

loading

Este manual también es adecuado para:

Dosipool ampero-panneauDoap23npsp-g5Doap23npsp-g5 panamp