IMMEDIATE AUTOMATIC
MESSAGE
DISPLAYED/FAULT
Amperometric
DETECTED
Alarm
pH injection
Alarm
CL injection
STOP
pH
regulation
regulation
No
Yes
Yes
No
POSSIBLE CAUSE
CHECKS AND REMEDIES
Ensure the pH corrector
container is not empty.
At the pH corrector
injection circuit, check
the condition of the:
- filter with ballast.
- semi-rigid pipes.
- of the peristaltic pump.
- injection connector.
Series of 5
Manually
unsuccessful
corrector.
attempts to
Check that:
correct the pH
- the peristaltic pump is
working properly.
- the pH corrector is
correctly injected.
Check the settings in the
pH Regulation
pH Regulation
and
menus.
Calibrate the pH probe.
Check
container is not empty.
At the chlorine injection
circuit,
condition of the:
- filter with ballast.
- semi-rigid pipes.
- of the peristaltic pump.
- injection connector.
Series of 5
Manually inject chlorine.
unsuccessful
Check that:
attempts to
- the peristaltic pump is
correct the
working properly.
chlorine
- chlorine is correctly
concentration
injected.
Check the settings in the
Dosing
Dosing
Parameters
menus.
Carry out an adjustment
of the free chlorine rate
measurement.
Alarms
inject
pH
Setpoint
Corrector
Parameters - Volume
the
chlorine
check
the
CL
Setpoint
Chlorine Rate
-
Volume
OPTION TO
DISABLE VIA
Settings -
MENU
Yes
Yes
15

Publicidad

loading

Este manual también es adecuado para:

Dosipool ampero-panneauDoap23npsp-g5Doap23npsp-g5 panamp