Descargar Imprimir esta página

Pool Technologie Dosipool Ampero Instrucciones De Uso página 35

Dosador de cloro por controlo amperométrico + regulador de ph

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
2.10.2. Important precautions regarding the peristaltic pump
When the following message is displayed, the peristaltic pump rotates.
Manual injection
XX:XX
INJECTION
I
In this case, do not remove the front panel of the electronics unit under any circumstances.
I
Do not put your finger in the rotating parts.
If case of doubt about the correct functioning of one of the peristaltic pumps:
1) Switch off the electronics unit.
2) Remove the cover of the electronics unit which covers the peristaltic pump.
3) Remove the internal pipe from the peristaltic pump, without removing the semi-rigid pipes connected to it .
4) Remove the front panel of the electronics unit
5) Check the condition of the peristaltic pump and internal pipes.
6) Turn on the electronics unit.
7) Carry out a manual vacuum injection.
8) Check that the peristaltic pump is running correctly .
Real-time countdown. Press OK to pause the injection or
Automatic regulation of ph or chlorine. Press Menu to pause the injection.
to stop it.
17

Publicidad

loading

Este manual también es adecuado para:

Dosipool ampero-panneauDoap23npsp-g5Doap23npsp-g5 panamp