B
Using the appliance
3. 0peration instructions
Display
When electrify the refrigerator, the display screen will total display for 3 seconds. Meanwhile
the starting up bell rings and then the screen enters the normal display of the operation.
The first time for using the refrigerator, the default set temperature of refrigerating chamber
and freezing chamber is 5 °C/-18 °C respectively.
When the error occurs, the display shows the error code (see next page); during normal
running, the display shows the set temperature of the refrigerating chamber or freezing
chamber. Under normal circumstances, if there is no operation on display panel or door
opening action within 30s, then the display is Iock, and the sate
Lock /unlock
In the unlocked state, long press the Iock button
The logo
goes outand buzzer sounds, il means the display panel is locked, at this time,
button operation cannot be implemented;
In the locked state, long press the Iock button
The logo
lights up and buzzer sounds, it means the display panel is unlocked, at this time,
button operation can be implemented;
Temperature setting of refrigerating chamber
Press temperature adjusting button of the refrigerating chamber
setting temperature of refrigerating chamber, and then each time a press of temperature
adjusting button of the refrigerating chamber, the temperature will be reduced 1 °C;
The temperature setting range for refrigerating chamber is 2-8 °C. When the temperature
is 2 °C, press the button again, and the temperature of refrigerating chamber will be set at
8 °C, and it circulates accordingly.
Temperature setting of freezing chamber
Press temperature adjusting button of the freezing chamber
temperature of freezing chamber and then each time a press of temperature adjusting
button of the freezing chamber, the temperature will be reduced 1 °C;
The temperature setting range for freezing chamber is -24 °C ~ -16 °C).
When the temperature is -24 °C, press the button again, and the temperature of freezing
chamber will be set at -16 °C, and it circulates again and again.
Thermostat setting for ambient T°C : NORMAL ° +24°C (± 4°C)
Thermostat setting for ambient T°C : COLD ° +16°C (± 4°C)
Thermostat setting for ambient T°C : HOT ° +32°C (± 4°C)
Mode setting
When super cool mode
is set, temperature of refrigerating chamber will automatically
set at 2 °C; Super cool exits for 6h.
Exit super cool mode
, temperature of refrigerating chamber will automatically return
back to temperature set before super cool mode.
12
goes out.
for 3 seconds, enter the Iock state.
for 3 seconds, enter the unlocked state.
to change the
to change the setting
3°C/-19°C
3°C/-19°C
3°C/-19°C
EN
B
Using the appliance
When super freezing mode
is set, temperature of freezing chamber will automatically
set at -24 °C; Super freezing exits for 24h.
Exit super freezing mode
, temperature of freezing chamber will automatically return
back to temperature set before super freezing mode.
When vacation mode AUTO is set, temperature of freezing chamber will be automatically set
at -18 °C; the temperature of refrigerating chamber will be automatically set at 5 °C.
Recommended setting: refrigerating chamber 3 °C, freezing chamber - 19 °C.
Fruit and vegetable box settings
When the lever is adjusted to the LOW position, the fruit and vegetable box is in low
humidity mode, and when the lever is adjusted to the HIGH position, the fruit and
vegetable box is in high humidity mode.
When the lever is adjusted to the COLD DRINKS position, the fruit and vegetable box
is in fresh mode, when the lever is adjusted to the DRY GOODS position, the fruit and
vegetable box is in treasure mode, and when the lever is adjusted to the FRUIT&VEG
position, the fruit and vegetable box is in fruit and vegetable mode.
Storage upon power failure
In case of power failure, the instant working state will be locked and maintained till
re-electrification.
Fault indication
The following warnings appearing on the display indicate corresponding faults of the
refrigerator. Though the refrigerator may still have cold storage function with the following
faults, the user shall contact a maintenance specialist for maintenance, so as to ensure
optimized operation of the appliance.
Error code
E1
Temperature sensor failure of refrigerating chamber
E2
Temperature sensor failure of freezing chamber
E4
Failure of defrosting sensor in refrigerating chamber
E5
Freezing defrost sensor detection circuit error
E6
Communication error
E7
Circulation of temperature detection circuit errer
EH
Moisture sensor error
13
Error description
EN