Dexxo Compact 600 io Dexxo Compact 750 io
1
A
A
B
A
Remote control "A" = "source" remote control already memorised
Remote control "B" = "target" remote control to be memorised
For example, if the button on remote control A opens the gate fully, the but-
ton on the new remote control B will also open the gate fully.
3.4
Operation of the gate safety
Opening the pedestrian gate integrated into the garage door prevents the
garage door from moving.
The integrated lighting is activated intermittently for 30 seconds.
3.5
Operation of the emergency manual back release
system
The emergency manual back release system allows the door to be moved
manually, for example in the event of a power outage. This device must be
able to be accessed easily, at a maximum of 1.80 m from the ground.
1.
Disengaging the motorisation: pull on the cord until the door drive sys-
tem is released.
2.
Manual manipulation of the door
NOTICE
This is possible as the drive system is released.
3.
Re-engaging the motorisation: move the door manually until the drive
mechanism locks onto the transmission rail.
CAUTION
When releasing the motorisation, an incorrect balance may result in sudden
movements which may be dangerous.
Only use the cord to release the motorisation.
Never use the cord to manipulate the door manually.
It is essential that the motorisation be re-engaged before any new com-
mands.
1
3
Copyright
©
2023 SOMFY ACTIVITES SA. All rights reserved.
2s
2
3
4
2s
B
B
2
4
MAINTENANCE
4.1
Checks
4.1.1
Safety devices
Check for correct operation every 6 months.
4.1.2
Backup battery
For optimum battery life, it is recommended that the main power supply be
switched off and the motor be operated using the battery for several cycles,
3 times a year.
4.2
Replacing the remote control battery
1
5
TECHNICAL DATA
GENERAL TECHNICAL DATA
Mains power supply
Max. power consumption
Standby consumption
Climatic operating conditions
Radio frequency
Number of memorisable channels
(One-way controls)
Programming interface
2
CR2430
or
CR 2032
220-230V - 50/60 Hz
100 W
< 0.5 W
- 20°C / + 60°C - IP 20
868 - 870 MHz, < 25mW
Complete/partial opening control:
30
Built-in lighting control: 4
4 buttons – 2 indicator lights
EN