Cold weather installations
An additional back draft damper non return valve should be
installed to minimize backward cold air flow and a thermal
break should be installed to minimize conduction of outside
temperatures as part of the vent system. The damper non
return valve should be on the cold air side of the thermal
break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup air
Local building codes may require the use of makeup air
systems when using ventilation systems with greater than
specified CFM of air movement. The specified CFM varies
from locale to locale.
Consult your HVAC professional for specific requirements in
your area.
Venting methods
This range hood is factory
set for venting through the
roof or through the wall.
You can apply the
recirculating venting
method by purchasing the
Recirculation Kit.
The vent system needed for
installation is not included.
A 6" (15.2 cm) round vent
system is recommended.
Roof venting
B
A
A. 6" (15.2 cm) vent through
the roof
A. Roof cap
6
Recirculating
A
B
A. 6" (15.2 cm) vent through
the cabinet
A. Round recirculating grid
Wall venting
A
B
A. 6" (15.2 cm) vent through
the wall
A. Wall cap
Electrical Requirements
I WARNING
PLUG INTO A GROUNDED 3 PRONG OUTLET.
DO NOT REMOVE GROUND PRONG.
DO NOT USE AN ADAPTER.
DO NOT USE AN EXTENSION CORD.
FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT
IN DEATH, FIRE, OR ELECTRICAL SHOCK.
IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA
70 (latest edition) or Canadian Electrical Code, CSA C22.1 No.
0-M91 (latest edition).
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is
also recommended. It is recommended that a separate
circuit serving only this range hood be provided.
This range hood is equipped with a power supply cord
having a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be plugged
into a mating, 3 prong, grounding-type outlet, grounded
in accordance with local codes and ordinances. If a mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
If provided with an electrical plug, connect the hood to
a receptacle that complies with current regulations and
placed in an accessible position. Where an electrical
plug is not provided (direct connection to electrical
network) or the plug will not be in an accessible position
after installation, place an approved bipolar switch in
accessible position that provides full disconnection under
overvoltage category III conditions, in accordance with
local wiring rules.
The grounded 3 prong outlet is to be located inside the
cabinet above the range hood at a minimum distance of
35
" (91 cm) from where the power cord exits the hood.
53
6 4
The grounded 3 prong outlet must be accessible after
installation of the range hood. See illustration:
35
" (91 cm)
53
6 4