CAUTION! Risk of burns from hot water!
After extended use against the closed pressure
side (> 10 min.), the water in the pump can be-
come very hot and may escape uncontrolled!
■
Disconnect the pump from the mains supply
and allow the pump and water to cool down.
■
Check the water level on the suction side.
■
Check the leak-tightness of the lines.
■
Check the installation of the suction and
pressure lines.
■
Put the pump into operation again only after
all the faults have been remedied!
3.1
General safety warnings
■
Appliances can be used by persons with re-
duced physical, sensory or mental capabili-
ties or lack of experience and knowledge if
they have been given supervision or instruc-
tion concerning use of the appliance in a safe
way and if they understand the hazards in-
volved. Children shall not play with the appli-
ance.
■
People with very strong and complex restric-
tions may have needs that exceed the in-
structions described here.
■
Pumps without indication that they are pro-
tected against the effect of freezing shall not
be left outside during freezing weather condi-
tions.
■
Never lift, transport or affix the pump by the
mains cable. Do not pull the mains cable in
order to pull the mains plug out of the socket.
■
Unauthorised modifications or conversions to
the pump are prohibited. Repairs may only
be carried out by our customer service.
■
Disconnect the mains plug before working on
the device. Protect the mains plug against
moisture.
■
Only use the pump and extension cable if
they are in flawless technical condition. Dam-
aged appliances must not be operated.
■
Maintain a safe distance to persons or ani-
mals or switch off the pump if animals ap-
proach.
3.2
Electrical safety
■
The pump may not be operated while people
are in the pool or pond.
■
The mains voltage at your location must com-
ply with the information regarding mains volt-
age in the Technical Data. Do not use any
other supply voltage.
14
■
The pump may only be operated on an elec-
trical installation in accordance with DIN/VDE
0100, parts 737, 738 and 702. For fuse pro-
tection, a circuit breaker of 10 A and an earth
leakage circuit breaker with a rated leakage
current of 10/30 mA must be installed.
■
Only use extension leads approved for out-
door use with a minimum cross-section of
2
1.5 mm
. Always fully unwind cable drums.
■
Damaged or fragile extension cables may not
be used.
■
Check the condition of your extension
lead prior to every use.
■
If the connection cable must be extended,
only a cable type H07RN-F and a moulded
sleeve must be used. This work must only be
carried out by an electrician.
■
If the supply cord is damaged, it must be re-
placed by the manufacturer, its service agent
or similarly qualified persons in order to avoid
a hazard.
4 INSTALLATION
4.1
Install the pump
1. Prepare a level and sturdy installation loca-
tion.
2. Install the pump horizontally and where it will
not be flooded.
■
The pump must be protected from rain and
direct water jets.
4.2
Connect the suction line
NOTE We recommend the installation of
flexible lines at the pump inlet to prevent me-
chanical pressure or tension being exerted on the
pump.
1. Select the length of the suction line such that
the pump cannot run dry. The suction line
must always be at least 30 cm under the wa-
ter surface.
2. Connect the suction line. Ensure that the
connection is tight, but take care not to dam-
age the thread.
3. Always lay the suction line with an upward
gradient.
NOTE If the suction head is more than 4 m,
a suction hose with a diameter larger than 1"
must be installed. We recommend the use of an
AL-KO suction unit with suction hose, suction fil-
ter and flow-back stop. Ask your specialist dealer.
JET 3000 - 3500 INOX CLASSIC | JET 3300
Installation