Descargar Imprimir esta página

Würth DIGA WO-KN 16/75 Traducción Del Manual De Instrucciones De Servicio Original página 34

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
2. Insert the gas cartridge [16] into the intake slot
with the dosing valve head up.
Note
Ensure that the nozzle [17] of the
dosing valve latches in to the red adapt-
er [18] on the device.
3. Close the cover [2].
Risk of severe injuries.
Small amounts of combustible gas
Â
may escape when the gas cartridge
is inserted.
Do not breath in gas, do not smoke.
¾
Keep it away from naked flames or
sparks.
If the smell of gas remains
perceptible after the gas cartridge
has been inserted, remove the gas
cartridge immediately and identify
the cause.
Note
The gas cartridge is not emptied
completely. In addition to fuel gas, the
gas cartridge also contains compressed
gas, which is used for pressure compen-
sation. There is always a small residual
amount of this pressure gas in the gas
cartridge for technical reasons.
Working instructions
Risk of severe injuries.
Unintentional triggering can result
Â
in injuries.
Switch off the device and remove
¾
the battery before any adjustment or
any removal/fitting of accessories.
Always hold the device firmly
¾
and be prepared for any sudden
reaction.
Functional check
Remove the battery from the device.
Remove all staples from the magazine.
34
WARNING!
WARNING!
Check the unhindered movement of the work-
piece contact by pressing it against a solid
surface.
Risk of severe injuries.
Do not use the device if the
¾
workpiece contact or the cocking
slide cannot move freely.
You can reload the magazine,
3
insert the gas cartridge and reinsert the battery.
3
Use the device.
Removing blockages
Risk of severe injuries.
Remove blockages with a suitable
¾
tool.
Use your personal protective
¾
equipment.
Remove the battery [7] from the device.
Pull the cocking slide [9] back until the cocking
slide release [10] latches in.
Remove the tangled nail or staple with some
pliers, if necessary.
If necessary, release the two fastening screws
[Fig. I / 14] from the top part of the magazine.
— Open the magazine in a forward direction.
— Fold the magazine back into the position be-
neath the nose of the device.
After removing the blockage, retighten the Allen
screws.
— When doing so, ensure a tightening torque of
4.5 Nm to max. 5 Nm.
You can reinsert the battery.
Note
The device deactivates automatically
and does not automatically restart.
To reactivate, remove and reinsert the
battery.
Reinsert the magazine strips.
Actuate the cocking slide release [10] and move
the magazine strip back until it is against the
staple strip.
The device is ready for use again.
3
WARNING!
WARNING!

Publicidad

loading

Este manual también es adecuado para:

Diga wo-sn 16/64Diga wo-hn 28/350864 950864 960864 97