C
C
Servicing safeguards
CAUTION
MICROWAVE RADIATION
1. The high voltage capacitor remains charge after disconnection; short the negative terminal
of H. V capacitor to the oven chassis (use a screwdriver) to discharge before touching.
2. During servicing below listed parts are liable to be removed and give access to potentials
above 250V to earth.
• Magnetron
• High voltage transformer
• High voltage capacitor
• High voltage diode
• High voltage fuse
3. The following conditions may cause undue microwave exposure during servicing.
• Improper fitting of magnetron;
• Improper matching of door interlock, door hinge and door;
• Improper fitting of switch support;
• Door, door seal or enclosure has been damaged.