SWITCHMATIC 2T SERIES CONTROLLER
14. WARNINGS AND ALARMS
COD.
DESCRIPTION
LACK OF WATER
LACK OF WATER
(DUE TO MINIMUM
PRESSURE)
OVER-CURRENT
EXCESSIVE
CYCLES
www.proindecsa.com / proindecsa@proindecsa.com
SYSTEM REACTION
When a lack of water is detected, it stops
the device. Operation resumes pressing ENTER.
When a lack of water is detected with the
Automatic Reset System (ART) activated, a first
attempt is made after 5 minutes and subse-
quently an attempt every 30 minutes for 24
hours. This alarm can also be reset manually
with the ENTER button. If the system persists
after 24 hours we find with a definitive lack of
water.
Appears if in normal operation the
pressure is below the minimum pressure
ma (Px.x)previously set during the time (txx)
previously established in the ADVANCED MENU.
If at any time the pressure exceeds the
minimum operating pressure automatically
restores.Normal operation may also be restored
manually by pressing ENTER.
Overcurrent alarm occurs if exceeds the rated
current of the pump. 4 automatic attempts are
made reset before proceeding
definitive alarm. Normal operation may also
be restored manually by pressing ENTER.
Only if we have activated it in the MENU
ADVANCED, the alarm is activated when
three consecutive cycles occur in a time
interval (between cycle and cycle) lower than
configured. If we have activated rc1, the device
is not stopped but add 5 seconds to the start
delay running to protect the electric pump.
If we have activated rc2, the electric pump
stops.To stop displaying the screen
alarm you must press ENTER.