TIG PRO 201 AC/DC - TIG PRO 201L AC/DC
2T MODE
Bouton principal
4T MODE
2
Bouton principal
4T LOG MODE
Bouton principal
2
ou
Bouton secondaire
For this mode it may be convenient to use the dual button torch option or dual button with potentiometer. The "up"
command keeps the same function as the single button or trigger torch. The secondary button can, when pressed,
switch to the cold current. The welding torch potentiometer, when present, allows the welding current to be adjusted
from 50 % to 100 % of the setpoint.
4
3
>0,5s
>0,5s>
0,5s
3
T1: The main button is pressed, the welding cycle starts (Pre-
Gas, I_Start, UpSlope and welding).
T2: The main button is released, the welding cycle is stopped
(DownSlope, I_Stop, PostGas).
For the double button torch and in 2T mode only, the se-
condary button works like the main button.
T1: The main button is pressed, the cycle starts at PreGas
and stops in the I_Start phase.
T2: The main button is released, the cycle continues in
UpSlope and in welding.
T3: The main button is pressed, the cycle switches to
DownSlope and stops in I_Stop phase..
T4: The main button is released, the cycle ends with PostGas.
T1: The main button is pressed, the cycle starts at
PreGas and stops in the I_Start phase.
T2: The main button is released, the cycle continues in
UpSlope and in welding.
LOG : this mode is used during welding :
- A brief press of the main button (<0.5s), the current
switches from I welding current to I cold and vice
4
versa.
- The secondary button is kept pressed, the current
switches from I welding to I cold.
- The secondary button is released, the current swit-
ches from I cold to I welding.
T3: A long press on the main button (>0.5 sec.), the
cycle switches to DownSlope and stops in the I_Stop
phase.
T4: The main button is released, the cycle ends with
PostGas.
EN
31