Press ZERO(↑) to reset the scale and put the objects to be weighed on platter.
3.4 Piece Counting Mode
The scale equipped with simple piece counting function, please follow the below procedure to
enable the function and sampling method.
a) Indicator is on and both Zero indicator and Stable indicator are on.
b) Press MODE(ENT) until display shows PCS as weighing unit on the display.
c) Press MR(↓) and display shows "S: 10", this means count 10pcs of the same item to put on
platter for sampling the average unit piece weight.
d) If 10pcs is not the prefer sampling quantity, continue to press ZERO(↑) and display will
show "S:20", "S:50", "S:100", "S:200", "S:500" and "S:1000". When the ideal quantity is
reached, press MODE(ENT) to confirm and put the sample quantity on platter. Do not load
the platter before pressing MODE(ENT) key.
e) Scales will begin the sampling process to calculate the unit piece weight, when the sampling
is done scale will show the sampled quantity on display.
f) Remove the load and put new batch, display will show the batch quantity.
g) If display shows a value while platter is empty, press ZERO(↑) to zero off the weight.
h) If a new sampling is needed, press and hold MR(↓) to start new sampling by following step
c to d.
NOTE:
1.
If scale detects the total weight of samples on the platter are smaller than 20d, the PCS sign
will start flashing as warning. Press ZERO(↑) key to change the sampling quantity setting or
add more samples until the signal is off.
2.
If scale detects the unit piece weight of the sample is smaller than minimum unit weight, the
PCS sign will start flashing as warning (unit piece weight must not small than 0.5d). It is
recommended using smaller capacity scale for this sampling.
3.
When PCS sign flashes, sampling process can still in process but might result errors.
10