use MODE(ENT) key to enter, ZERO(↑) to change, MODE(ENT) key to confirm
d. Press MODE(ENT) to confirm and exit the current function, display shows "Fn12".
e. Press MODE(ENT) to enter the next function, or press ZERO(↑) to exit. When ZERO(↑) is
pressed, display will show "SAVE" if setting was changed, user can either press MODE(ENT) for
yes to save the changes made or press ZERO(↑) for not to save the changes.
Terminology:
nonE: no data output
bAud: baud rate
transmission type
4.12.1 Transmission Mode
StrM: stream mode, data continuous sending when stable (ForMt only has Ser.1 available)
ST, NT,
ST, NT,- 100.01kg
..................................
Manu: manual mode, data sends once when manually pressing keypad (press M+/MC(←) to
send one data, press M+/MC(←) to clear memory and send total value)
set at "Ser.1".
Press M+/MC(←) to send single data (as "Ser.1" formt), and will not print total value.
NOTE:
1. When tare is not used, net weight equals to gross weight, so RS-232 will transmit data in NET
status.
When format is set at "Ser.2"
Press M+/MC(←) to send single data, press M+/MC(←) to send total value (as "Ser.2" format)
S/N WEIGHT UT
1
100.02 kg
2
99.01 kg
ForMt: transmission format
100.01kg
press M+/MC(←) to print single data
H
G
rS232: data output through RS-232 only
ProtL: transmission protocol trAns:
When format is
17