OPERATING AND MAINTENANCE MANUAL
SWITCHMATIC SERIES CONTROLLER
4. Enter stop pressure:
- Press
for 3 seconds.
- The stop pressure flashes on the display and the STOP LED lights up.
- Use the buttons
- Press
to validate.
5. The device is configured, however, there are many possibilities for adjustments to be
made via the basic and advanced programming menus. See next chapter.
Note 1: It is important to enter exactly the rated current specified on the nameplate of
the pump.
10. BASIC PROGRAMMING MENU
- Press
+
for 5 seconds.
- Use the keys
or
- Press
to validate and move on to the next.
- The sequence of parameters is as follows:
IT
TYPE
1
BAR PSI
2
rc0 rc2
2.1
r.01 r.99
4
Sb0 Sb1
www.proindecsa.com / proindecsa@proindecsa.com
and
to set the stop pressure from 1 to 8 bar (+ version =12 bar)...
to change the values.
SYSTEM REACTION
Allows selection of the units in which the
pressure is displayed between bar and psi.
Fast cycle alarm:
- rc0: alarm deactivated.
- rc1: alarm activated, when detected there
is a delay in the start-up to protect the
- rc2: alarm activated and the pump stops
Only if we have activated in the previous
step the fast cycle alarm (rc1&rc2), we
can select the period of time between
3 consecutive start-ups, in seconds, we
consider as fast cycle between 1' and 99'.
Allows to activate the display stand-by
mode (Sb1) or to deactivate it (Sb0) to save
(diagram C)
+
pump.
when detected.
energy.
18
DEFFECT
BAR
rc2
3 SEGUNDOS
Sb1