8
TROUBLESHOOTING
PROBLEM / SYMPTON
LED module will not light
Low light output
MULTIFUNCTION FLOODLIGHT TOWER
WARNING!
HIGH VOLTAGE! This unit uses high voltage circuits capable of causing serious injury or
death. Only a qualified electrician should troubleshoot or repair electrical problems
occurring in this equipment.
REASON
Faulty LED module connection
Fuel tank has no fuel.
Plug connection at fixture is
loose or damaged.
LED module broken or burned
out.
Circuit breaker is turned off.
Circuit breaker is loose or
defective
Generator output is incorrect.
LED module degraded
Fixture or lens dirty
REMEDY
Check that lamp connectors
are tight and or not damaged.
Check connections inside
connection boxes on light
fixtures and tower.
Have a licensed electrician
repair or replace the plug
connection.
Check for:
Turn on circuit breaker.
Have a licensed electrician
repair or replace the circuit
breaker.
If voltage is incorrect, engine
speed may need to be
adjusted or generator may
require service.
Replace LED module due to
normal LED module life.
Clean
reflective
inside fixture and outside
surface of glass lens.
STELLA
en
surface
29