x2
***
0---
10--
ALT
follow the user guide
Add. 1ch
hidden butt
Add. 2ch
hidden butt
Add. 3ch
hidden butt
Add. 4ch
hidden butt
erase 64
erase 1
( 0001 )
language
**
autoset
Control unit
software version
stat
vers
OK
bft . . .
+/-
- +
No total
manoeuvres(in hundreds)
OK
0000
n. cycles
+/-
- +
No radio control
devices memorised
00
n. remotes
OK
+/-
- +
List of last 30 errors
01.33
err
OK
02.01
........
30.15
+/-
0---
password
** Only active on LEO B CBB 3 230 L02
ACCESS MENUS Fig. 1
INSTALLATION MANUAL
150-
1520
ok
See PARAMETERS MENU
See LOGIC MENU
release
desired button
release
desired button
release
desired button
release
desired button
ok
If cancelled
KO
If not present
If clone, it is disabled
dis
Diagnostics code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
Activation of PHOT photocell input or, if configured as verified photocell,
PHOT
Activation of the associated FAULT input
Activation of PHOT OP opening photocell input or, if configured as
active verified photocell only when opening, Activation of the asso-
PHOP
ciated FAULT input
Activation of PHOT CL closing photocell input or, if configured as active
verified photocell only when closing, Activation of the associated
PHCL
FAULT input
Activation of BAR safety edge input or, if configured as verified safety
BAR
edge, Activation of the associated FAULT input
Activation of BAR safety edge input on slave motor (opposing door
connection) or, if configured as verified safety edge, Activation of the
BAR 2
associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE OPENING,
or, if configured as verified safety edge active only while opening, Activation
baro
of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE CLOSING,
or, if configured as verified safety edge active only while closing, Activation
barc
of the associated FAULT input
SWC motor closing limit switch input activated
SWC
SWO motor opening limit switch input activated
SWO
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in or-
SET
d e r t o a c q u i re t h e t o rq u e re q u i re d fo r m o ve m e n t .
WARNING! Obstacle detection not active
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
Safety edge test on slave motor failed (opposite leaves connection)
ER05
8k2 safety edge test failed
er06
Opening safety edge test failed
ER07
Closing safety edge test failed
ER08
Board hardware test error
ER1x*
Reverse due to obstacle - Amperostop
ER3x*
Communication error with remote devices
ER5x*
ER70, ER71
Internal system supervision control error.
ER74, ER75
Consistency error of the control unit's parameters (Logics and Parameters)
ER72
D-track parameter error
ER73
Limit switch error
ERf0
Limit switch error always active after operation start
erf1
Error in setting the SAFE inputs
ERf3
*X= 0, 1, .., 9, A, B, C, D, E, F
10--
150-
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
See RADIO MENU
35. 4 0
DESCRIPTION
1520
prg
Scroll up
Scroll down
Con rm/Switch on display
Exit Menù
Obstacle threshold
Instantaneous force motor
NOTES
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/
logic setting
Check photocell connection and/or parameter/
logic setting
Check safety edge connection and/or parameter/
logic settings
Check safety edge connection and/or parameter/
logic settings
Check safety edge connection and/or parameter/
logic settings
Check safety edge connection and/or parameter/
logic settings
-Check connections to motor
-Hardware problems with board (contact technical assistance)
Check for obstacles in path
Check connection with serial-connected accessory devices
and/or expansion boards
Try switching the board off and back on again. If the
problem persists, contact the technical assistance
department.
Pressing OK the detected settings are confirmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track
as a default.
An autoset is required
check limit switch connections
Check limit switch and motor connections
Check the setting of the SAFE inputs is correct