Descargar Imprimir esta página

General Information; Technical Specifications - BFT LEO B CBB 3 230 L02 Instrucciones De Instalación

Ocultar thumbs Ver también para LEO B CBB 3 230 L02:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 60

2) GENERAL INFORMATION

The LEO B CBB 3 230 L02- LEO B CBB 3 120 F02 control panel comes with
standard factory settings. Any change must be made using the programmer with
built-in display or universal handheld programmer. The Control unit completely
supports the EELINK protocol.
Its main features are:
-
Control of 1 single-phase motor
-
Electronic torque control
-
Obstacle detection (only on LEO B CBB 3 230 L02 e LEO B CBB 3 120 F02)
-
Separate inputs for safety devices
-
Configurable command inputs
-
Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77. If the above-
mentioned terminals are being used, remove the relevant jumpers.
LEO B CBB 3 230 L02
Power supply
220-230V~ 50Hz/60Hz
Obstacle
detection with
Present
encoder
Output for
terminals 26-27:
AUX3 configurable
N.O. contact
(24V~/0,5A)
TESTING
The LEO B CBB 3 230 L02- LEO B CBB 3 120 F02 panel controls (checks) the
start relays and safety devices (photocells) before performing each opening
and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
WIRING AND TERMINAL BOARD CONFIGURATION
Terminal
L
N
GND
10
11
12
AUX 0 - POWERED CON-
TACT 220 230V~
20
(LEO B CBB 3 230 L02)
POWERED CONTACT 120V~
(LEO B CBB 3 120 F02)
21
26
AUX 3 - FREE CONTACT
27
41
42
43
JP32
50
51
52
60
61
62
63
64
65
34 -
LEO B CBB 3 230 L02 - LEO B CBB 3 120 F02
INSTALLATION MANUAL
LEO B CBB 3 120 F02
120V~ ±10% 50Hz/60Hz
Present
Output for audible signal
Definition
Single-phase power supply
LINE
(LEO B CBB 3 230 L02).
NEUTRAL
Single-phase power supply 120V~ ±10%, 50-60Hz, with earth cable
EARTH
(LEO B CBB 3 120 F02).
START + CAP
Motor connection.
START + CAP Motor Start and capacitor
COM
COM Motor Common
START + CAP Motor Start and capacitor
START + CAP
AUX 0 configurable output - Default setting FLASHING LIGHT.
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/
GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING LIGHT AND MAINTE-
NANCE / ANTITAMPERING / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to "AUX output configuration" table.
A U X
1
MONOSTABLE RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/
STAIR LIGHT/ GATE OPEN ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK/ MAINTENANCE/ FLASHING
(N.O.)
LIGHT AND MAINTENANCE /ANTITAMPERING / GATE STATUS / BISTABLE RADIO CHANNEL / TIMED RADIO CHANNEL.
Refer to "AUX output configuration" table.
+ REF SWE
Limit switch common
SWC
Closing limit switch SWC (N.C.). (Do not connect or jump if there is the magnetic limit switch)
SWO
- Opening limit switch SWO (N.C.). (NDo not connect or jump if there is the magnetic limit switch)
Magnetic limit switch connection
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
24 Vsafe+
Output active only during operating cycle.
Common
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 2 (N.O.) - Default PED.
IC 2
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Common
IC 3 and IC 4 inputs common
Configurable command input 3 (N.O.) - Default OPEN.
IC 3
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 4 (N.O.) - Default CLOSE.
IC 4
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.

3) TECHNICAL SPECIFICATIONS

Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Maximum motor power
Accessories power supply
AUX 0
AUX 3/ Output for audible signal
Dimensions
Fuses
N° of combinations
Max.n° of transmitters that can be memorized 63
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. B
WARNINGS - When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying different voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
220-230V
50/60Hz
~
, with earth cable
c o n f i g u r a b l e
o u t p u t
220-230V~ 50Hz/60Hz
(LEO B CBB 3 230 L02)
120V~ ±10% 50Hz/60Hz
(LEO B CBB 3 120 F02)
> 2MOhm 500V
-20 / +55°C
Built into motor
mains/LV 3750V~ for 1 minute
750W
24V~ (demand max. 1A)
24V~safe
220-230V~N.O. (40W max)
(LEO B CBB 3 230 L02)
powered contact
120V~N.O. (40W max)
(LEO B CBB 3 120 F02)
powered contact
NO contact (24V~/max.0,5A)
146x170x60mm
see Fig. B
4 billion
Description
-
D e f a u l t
s e t t i n g
Z O N E
L I G H T
O u t p u t .

Publicidad

loading

Este manual también es adecuado para:

Leo b cbb 3 120 f02