Maintenance - SMA SUNNY TRIPOWER 60 Instrucciones De Instalación

Ocultar thumbs Ver también para SUNNY TRIPOWER 60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4  Service
ID
Description
356–
Transistor and relay test failed or inverter
361
relay has failed (contact assumed
welded).
366
Residual-current monitoring unit (RCMU)
self-test failed.
Table 4.5 Events caused by the self-test

4.2 Maintenance

Ensure that the heat sink at the rear of the inverter is not
covered.
Clean the contacts of the PV load-break switch once a year.
Clean by cycling the switch to on and off positions ten times.
The PV load-break switch is located at the bottom of the
inverter.
For correct operation and a long service life, ensure free air
circulation for the following areas:
• around the heat sink at the top and side of the inverter
where the air exhausts, and
• to the fan at the inverter base.
To clear obstructions, clean using compressed air, a soft
cloth, or a brush.
Temperature of the heat sink can exceed 70°C.
44
STP60-10-IA-xx-10
Measure
Contact the Service.
Contact the Service.
SMA Solar Technology AG
DGO
Hotline
PV
-
-
-
-
-
-
Installation Guide

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido