►►4.3. DISCHARGE PIPE CONNEC-
en
TION (Set-up)
it
(FIG. 6)
A discharge pipe can be connected to the ap-
de
pliance. A hose connection with a diameter of
es
16 mm is fitted on the tank.
fr
►►4.4. CONNECTION OF THE CON-
nl
DENSATE PUMP (Optional)
pt
Depending on the model, the appliance
da
can be set up for the connection of the con-
densate discharge pump.
fi
For a correct connection, disconnect the unit
no
from the power supply before carrying out any
operation.
sv
For a correct installation of the condensate
pump, refer to the technical manual included
pl
in the optional kit.
ru
cs
hu
►►►5. MAINTENANCE
sl
tr
►►5.1. CHECKS TO BE PERFORMED
BY THE USER
hr
(FIG. 7)
The only maintenance to be carried out by the
lt
user is the cleaning of the air filter, which must
lv
be performed at least once a month.
The cleaning frequency can be increased due
et
to the dustiness of the working environment of
ro
the appliance.
sk
CAUTION: REMOVE THE FILTER FROM
bg
THE APPLIANCE TO PERFORM CLEANING.
IT IS FORBIDDEN TO PERFORM CLEAN-
uk
ING WITH THE FILTER INSTALLED.
bs
el
►►5.2. SPARE PARTS
Should it be required to replace one or more
zh
parts during maintenance by specialised op-
erators, this must be done by using original
spare parts only.
If required, request the "spare parts list" from
your vendor, specifying the model and serial
number of the unit.
►►5.3. DISMANTLING THE UNIT
The unit has been designed and built to en-
sure continuous operation. The lifespan of
some components such as the fan and the
compressor depends on their maintenance.
CAUTION: The unit contains sub-
stances and components dangerous for the
environment (electronic components, refriger-
ant gas and oils). At the end of its useful life, in
the event of dismantling the unit, the operation
must be carried out by specialised refrigerat-
ing personnel.
The unit must be sent to specific special-
ised centres for the collection and disposal of
equipment containing dangerous substances.
The refrigerant fluid and the lubricating oil
contained in the circuit must be recovered,
in accordance with the regulations in force in
your country.