AT-6000-EUR
Tracing Energized and De-energized Wires
Set-up:
1
Test Leads
AT-6000-TE
TRANSMITTER
HI
LO
Proper connection
with separate
ground
1. Connect the green and red test leads to the
Transmitter.
2. Plug the socket adapter onto the receptacle and
connect the red lead to the Energized hot wire.
The signal will only be transmitted between the
load-side to which the Transmitter is connected
and the source of power.
3. Connect the green wire to a separate ground.
Set-up:
2
Transmitter
Blinking
Transmitter
indicator showing
signal in
HIGH mode
1. Turn on the Transmitter.
2. Verify that the test leads are properly connected;
the red LED voltage status light should be on
for circuits with voltage above 30 V AC/DC, and
it should be off for De-energized circuits below
30 V AC/DC.
3. Select HIGH signal mode by pressing HI, LED
display will quickly begin to blink.
2
Beha-Amprobe
®
AT-6000-TE
TRANSMITTER
HI
LO
Receiver:
Quick Scan Mode
Use this mode to easily follow the direction of a wire.
NCV
Signal not detected
1. Turn on the Receiver. It will automatically start in
Quick Scan Mode.
2. Scan the target area with the Tip Sensor to find
a signal, then begin tracing the detected wire.
Increase or decrease sensitivity of the Receiver by
pressing + or - on the keypad as necessary.
Receiver:
Precision Tracing Mode
Use this mode to precisely pinpoint the wire,
within 1" accuracy.
Precision
tracing mode
1. Turn on the Receiver. Press the MODE button until
the Precision Tracing function is selected.
2. Scan the target area with the Tip Sensor to find
the highest signal level. While tracing, periodically
adjust sensitivity to keep the signal strength near
50. Increase or decrease sensitivity by pressing + or -
on the keypad. If the signal is too strong for precise
locating, change the Transmitter to LOW mode.
NCV
Signal detected
88
NC V
AT-6000-RE