INSTRUCTION FOR USE
Battery installation
3.
Open the recovery tank cover (5, Figure 1) and check that the recovery tank (9, Figure 1) is empty; otherwise empty it with the
drain hose. (4, Figure 1)
4.
Close the recovery tank cover (5, Figure 1).
5.
Move the recovery tank kit (A, Figure 3) carefully.
6.
The machine is supplied with cables suitable to install 2X12V batteries. Carefully put the batteries into the compartment, then install
them correctly.
7.
Route and install the battery cable as shown in (Figure3), then carefully tighten the nut on each battery terminal.
8.
Place the protection cap on each terminal, then connect the battery connector (B, Figure 3).
9.
Carefully put it back the recovery tank kit (A, Figure 3).
Battery charging
10. Charge the batteries. (See procedures in maintenance chapter).
CAUTION!
Cut off all the power of the machine before perform the following procedure!
Battery charger setting
11. Remove the screws (A, B, C, Figure 4.1).
12. Open the charger and find the sw1 (D, Figure 4.1).
13. Set the switches as the table of Figure 4.1.
14. Install the screws (A, B, C, Figure 4.1) after setting complete.
A
C
B
SW1
ON
OFF
DP1 DP2
DP1 DP2
ON
D
OFF
OFF
ON
Figure 4.1
CHARGING CURVE
OFF
IUIa Wet
OFF
ON
IUUa Fullriver AGM
ON
IUIa Discover AGM
13
ENGLISH