CEX-U ELECTRONIC MPS ® / CEX ELECTRONIC MPS ®
2. How to use
EN
Set temperature
1
–1 °C
Convenience zone 35,0..42,0 °C
1
– 0,5 °C
Select preset temperature
A1
B1
Store temperature
1
Set required
temperature
(e.g. 43 °C)
4
Display of new value
(e.g. 43 °C)
Temperature limit
1
Temperature limit off
1
+
Press
≥ 3 sek
As soon as you open the hot water tap, the instantaneous water heater switches
on auto matically. When the tap is closed, the appliance automatically switches
off.
Temperature setting
You can set the required temperature gradually to a lower or higher value with the
arrow keys
The temperature changes by 1 °C, in the convenience zone between 35 °C and 42 °C by
+1 °C
0.5 °C, if key is pressed shortly one time. Pressing a key for a longer time changes the
temperature continuously.
Note: If temperature is set below 20 °C with arrow key
and the appliance switches off the heating function.
+0,5 °C
Note: If the water heater supplies a shower, the maximum temperature was
reduced during initial operation. This limitation cannot be exceeded.
Programme buttons
A2
The two programme buttons allow to quickly select the preset temperature. When
pressing a programme key, the preset temperature is selected and displayed. The fac-
tory setting for programme
B2
your own settings for the programme keys:
• Prolonged pressing of the programme key stores the previously selected tem-
perature. The display changes from "P1" or "P2" to the newly stored temperature
value. This newly set temperature is now available to you each time you press the
2
corresponding program key.
Press
≥ 3 sec
3
Temperature limitation
This instantaneous water heater is equipped with an optional temperature limiting
on
2
function. This scalding protection is deactivated in the factory setting.
+
• Switch on: Select the limit tempe ra ture, then press
least 3 sec. The dis play briefly confirms the activation by "HI".
Press
≥ 3 sec
• Switch off: press program key
play briefly confirms the deactivation by "--".
Note: By activation of the temperature limit also the programme keys are affect-
ed. Therefore, the fixed values of the programme keys must be checked after
2
changing the temperature limitation.
Confirmation
of deactivation
and
.
is 35 °C and for programme
and
simultaneously for at least 3 sec. The dis-
8
the display shows "--"
it is 48 °C. You can assign
and
simul taneously for at

Publicidad