IT IS HIGHLY RECOMMENDED THAT PROFESSIONAL STYLE COOKING ALWAYS BE VENTED
TO THE OUTSIDE. For recirculating installations (Figure 1), Charcoal Filters are necessary. Remove
all grease filters and set aside. Attach one charcoal filter to each end of the blower. Each charcoal filter
attaches to the grid on the side of the blower. Rotate the filter clockwise to install and counterclockwise
to remove (Figure 1A). Replace all grease filters. Recirculating installations also require some duct work
to divert the air out of the top or face or side of the cabinet or custom hood or out of the side / face of
the soffit and back into the kitchen. Install at least 15" of vertical run of metal duct (Figure 1) at the air
outlet. Run the duct vertically and secure it at the relevant opening previously cut out at the top or side
of the cabinet or soffit. A metal duct cover grille is also recommended. The duct work must not terminate
inside the cabinet or custom hood.
cabinet
or
duct
work
custom
hood
inca pro plus
FOR ALL INSTALLATIONS REMOVE ALL WHITE PLASTIC PROTECTIVE COVERING FROM
HOOD, SIDE RAILS, TRIM, GREASE RAILS AND GREASE FILTERS.
INSTALLATION WITH IB300 / IB400 / IB600 INTERNAL BLOWER
1. Install the Plate B (Figure 2) which came with
the internal blower kit, on top of the rangehood
with the hole closer to the back of the hood. Use 9
screws supplied with the blower kit.
FIGURE 2
8
RECIRCULATING INSTALLATIONS
ceiling
cabinet
or
custom
hood
duct
work
inca pro plus
(300, 400, 600 cfm)
B
ceiling
FIGURE 1
2. Remove the white plastic covering and install
the 4 side trim pieces (4-5) to the outside of the
hood using (14) part 9c screws, see the side trim
installation in (Figure 3).
9c
5
4
FIGURE 3
FIGURE 1A
FIGURE 4A
4
5