Descargar Imprimir esta página

Jackson WH50 Multiview Instrucciones De Uso página 5

Casco para soldar papr incorporado al sistema respiratorio

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15
IMPORTANT NOTICE
Please read these instructions carefully before using this product. Failure to comply with the instructions provided in this leaflet or any alternation made
to adapt to other protective devices may void your limited product warranty and adversely affect your health and safety. The selection of this PPE
device should be the result of the risk assessment conducted by a professional health and safety officer. Its use should be strictly in accordance to the
instructions provided along with the product. If you have any questions regarding the suitability of this product for your assigned task, please contact your
designated health and safety supervisor and/or contact Surewerx for advice. Before using the welding helmet please reassure the product is equipped
with a Jackson Safety
mineral glass or Auto Darkening Filter (ADF) suitable for your selected welding application.
®
SELECTION, USE, STORAGE AND MAINTENANCE
Jackson Safety
welding helmets offer reliable protection for eyes and face during welding related activities. Surewerx offers a range of fixed and variable
®
filters (ADF) filters that are suitable to be incorporated to this welding shield for various welding applications. Please follow the table below as a guidance
for filter selection of the most appropriate filter for your specific application. Jackson Safety
system offer additional protection against solid and airborne particles as per certified TH2P R SL classification. Surewerx offers multiple eye filters for the
wearer to select the most appropriate filter shade or range of shades.
Welding process
Or related techniques
E Manual
Flux core electrodes
Fluxed stick electrodes
MIG / Metal-Inert-Gas Argon (Ar/He)
Steels, alloyed steels,
Copper & its alloys etc
MIG / Metal-Inert-Gas Argon (Ar/He)
Aluminium, copper, nickel
And other alloys
TIG / Tungsten-Inert-Gas Argon (Ar/H₂) (Ar/He)
All weldable metals such as: steels, aluminium,
copper, nickel their alloys
MAG / Metal-active Gas (Ar/CO₂O₂) (Ar/CO₂/He/H₂)
Construction Steel, hardened & tempered steels
Cr-Ni-steel, Cr-steel & other alloyed steels
Electric arc compressed air joining
(Melt joining) carbon electrodes (O₂)
Flame grooving compressed air (O₂)
Plasma cutting (fusion cutting)
All weldable metals see WIG
Centre and outer gas: Argon (Ar/H₂)(Ar/He)
Plasma cutting (fusion cutting)
Micro-plasma welding
Centre and outer gas: Argon (Ar/H₂)(Ar/He)
All welding helmets are supplied with multiple lens and filter retainers, so the user can fit the selected filter solution. Always use CE marked Jackson
Safety
welding filters.
®
Jackson Safety
head tops are ready to use units, simply adjust the head gear in the three ways indicated in drawing 1 to obtain the most comfortable
®
configuration.
Clean only with mild soap and water. Dry with a clean cotton cloth. The use of solvents is strictly prohibited, as they will damage the components. If
disinfection is needed, contact Surewerx for advice. Face seal of the head top that works in conjunction with the AIRMAX
be removed from the face shield and mechanically washed with a mild soap and water and then allowed to dry overnight in a ventilated area.
Always store this product in the container provided, protected from mechanical impacts and away from hot surfaces.
Keep in a dry, clean condition away from direct sunlight and chemical and abrasive substances.
We recommend you to use the welding helmet for a period of 10 years. The duration of use depends on various factors such as way of use, cleaning,
storage and maintenance. Frequent inspections and replacement in case of damage are recommended.
Explanation to the marks that accompany the CE mark:
JS and/or SM: Identification of the manufacturer: Jackson Safety and/or Surewerx Manufacturing
S: Increased robustness
F: Mechanical strength against low energy impact at 45 m/s
B: Mechanical strength against medium energy impact at 120 m/s
1: Optical class 1 for continuous use
P SL: The letters P and SL indicate protection against solid and liquid airborne particles
R: The letter R indicates that the particulate filter is reusable at the end of shift
6
0.5
2.5
10
20
1
5
15
8
8
4
5
6
7
8
9
10
1
5
15
0.5
2.5
10
20
Depending upon the application conditions, the next highest or next lowest protection level can't be used.
The darker fields correspond to those areas in which the corresponding welding process cannot be used.
head tops incorporated to the R60 AIRMAX Respiratory
®
Current internally in amperes
40
80
125
30
60
100
150
10
11
9
10
11
10
11
9
10
11
10
11
12
10
11
12
11
30
60
100
150
40
80
125
175
225
275
350
200
250
300
12
12
12
13
12
13
13
11
12
13
12
13
13
14
200
250
300
175
225
275
350
R60 Respiratory system can
®
450
400
500
13
14
14
13
14
14
14
400
500
450