Priming Program
The installer should set the priming speed to be sufficient for priming the pump from a fresh
install, but not so fast that there is a substantial waste of energy. The time the pump needs
to achieve prime can change based on local environmental conditions such as water temper-
ature, atmospheric pressure, and your pool's water level. All of these things should be taken
into consideration when setting the priming speed.
This feature is disabled by default. To enable priming program:
• Ensure the pump is in STOP mode by cycling the START/STOP button until the red LED above
it is not lit.
• Long press DISPLAY button for 6 seconds to enter the priming settings.
• While in this menu, use the < and > arrows to cycle between options.
• The default priming speed is 3400 RPM. Use the + and - arrows to set this to your desired
speed between 2000-3450 RPM.
• The default duration is 0 minutes which means this feature is disabled. Set duration more
than 0 minutes to activate this feature.
• Use the + and - arrows to set this to your desired duration between 0-10 minutes.
• Long press DISPLAY button for 2 seconds to save the settings.
Clock Set
When the pump is first installed, it is necessary to set the clock. It must be based on a daily
schedule set by the user.
ATTENTION:
Below Steps 1-4 are used for Schedule Mode and Manual Mode. Step 5 is only used for Schedule
Mode.
If the power goes out, the driver retains a memory of settings for next 24 hours. The clock
have to be re-set again if the power is out more than 24 hours. Otherwise, the program will
automatically run as speed 1 and start to blink.
Clock set steps:
1. When power is applied to the pump, the Time LED light will begin blinking and you must
press the Display button within 5 seconds to enter the clock setup mode. (If Display button
is not pressed within 5 seconds, you may press "<" and ">" together for 3 seconds to begin
again. The time LED light will begin blinking. Quickly press the Display button within 5 sec-
onds to enter the clock setup mode.)
2. Pressing the arrows to choose between a 12 or 24 hour time format.
3. Pressing the "+" and "-" buttons to change the displayed time to the correct time of day. In
the 12 hour time format AM/PM will display in the bottom left corner.
4. To exit the clock setup mode, press and hold the Display button until the TIME light goes
out. The clock is now set.
In Schedule mode, Press START and allow pump to run on Default Schedule for at least one
OFF-ON cycle. If motor does not start, press any speed button.