several times until the display shows EP 1 or use
Down button to disable economy mode, the display
will show EP 0. Wait 15 seconds to allow the exit
timer to expire and store the setting.
FAHRENHEIT/CELSIUS SETTING:
To change water temperature display to either
Fahrenheit or Celsius, press and hold Light button
for 5 seconds until F1 is displayed. Press the Light
button several times until F or C
Press the Up/Down button to change. Wait 15
seconds to allow the exit timer to expire and store
the setting.
DIAGNOSTIC LCD MESSAGE
Message Meaning
No message on display.
Power has been cut off to the spa.
HL
The system has shut the heater off be-
cause the temperature at the heater has
reached 122°F (50°C). Do not enter the
water!
AOH
Temperature inside the equipment
compartment is too high 194°F (90°C),
causing the internal temperature in the
control system to increase above normal
limits.
PRR
A problem is detected with the
temperature probe.
OH
The water temperature in the spa has
reached 108°F (42°C). Do not enter the
water!
UPL
No low level configuration software has
been installed into the system.
FLO
No water flow is detected by the control
system but flow is expected.
CONTROL PANEL OPERATION
is displayed.
WARNING! DO NOT ENTER SPA IF
WATER IS TOO HOT
Water is too hot. Overheat protection heater
is deactivated. Spa water temperature is above
acceptable limits. When the actual water
temperature is approximately 2º F (1º C) above the
set temperature, the jet pump will stop operating
to reduce (frictional) heating. If the spa water
temperature continues to rise and gets above 108º
F (42ºC), the spa will go into an "OH" overheat
condition.
Action Required
The control panel will be disabled until power
returns. Spa settings will be preserved until next
power up.
DO NOT ENTER THE WATER. Remove the spa
cover and allow the water to cool down, then shut
power off and power your spa up again to reset the
system. If spa does not reset, shut off the power to
the spa and call customer service at (888) 961-7727
Ext. 8440 or at ahsservice@watkinsmfg.com.
Open equipment compartment and wait until error
clears.
Call customer service at (888) 961-7727 Ext. 8440
or at ahsservice@watkinsmfg.com.
Remove the spa cover and allow the water to cool
down to a lower temperature. Call customer service
at (888) 961-7727 Ext. 8440. if problem persists.
Call customer service at (888) 961-7727 Ext. 8440
or at ahsservice@watkinsmfg.com.
Make sure that the jet pump is running and water
is flowing; check and clean filters; make sure water
valves are open; make sure spa has a proper water
level. If problem persists, call customer service
at (888) 961-7727 Ext. 8440 or at ahsservice@
watkinsmfg.com.