CONTROL UNIT INDICATORS (LEDS)
The highlighted boxes indicate the state of the LEDs when the
roller shutter is resting.
LED
ON
START
START1 input closed
IN2
START2 input closed
STOP
STOP input closed
PHOTO
PHOTO input closed
EDGE input closed
(edge not pressed)
Resistive rubber edge
EDGE
EDGE input closed
(edge pressed)
Edge NO pressed: 8K2
between EDGE input
and common (-)
mains
Control unit powered-up
Accessory power supply
overload
overload
CABLE GLAND ASSEMBLY
The casing can accept 4 cable glands in the special easy-break
housings. The type of cable gland is indicated in the figure.
m
PLEASE NOTE:
• Remove the electronic circuit board before drill the casing.
• Drill the container using a suitably sized cutter, according to the
dimensions of the cable gland.
• Fix the cable glands using the special nuts
PG9 - PG11
PG9 - PG11 - PG16
OFF
START1 input open
START2 input open
STOP input open
PHOTO input open
Standard edge
EDGE input open (edge
pressed)
EDGE input open
(fault)
Control unit NOT
powered-up
Accessory power
supply within normal
operational limits
INSTALLATION
Installation of the control unit, the safety devices and accessories
must be performed with the power supply disconnected.
POWER SUPPLY
The control unit must be powered by means of a 230 V - 50 Hz
or 120 V - 60 Hz power line, depending on the model, protected
by a differential magnetothermal switch in compliance with legal
regulations.
Connect the power cables to the control unit L and N terminals.
MOTOR
The controller can drive an alternating current asynchronous
motor equipped with limit switch.
Connect the cables for motor as follows:
• Opening cable to terminal C1
• Closing cable to terminal C3
• Common return cable to terminal C2
BLINKER
The control unit provides for the use of a 230 V - 40 W or 120 V -
40 W blinker with built-in intermittence.
Connect the cables to terminals D3 and D4
COURTESY LIGHT
This output has a normally-open clean contact relay which closes
for approx. 1 second at the start of an opening phase. This switch
may be used to activate a courtesy light timer (max. load: 230V -
4A).
PLEASE NOTE: If there is no timer, the courtesy light can be
controlled using channel 4 of receiver MR: bistable or timer
programmable channel (read the instructions for the receiver MR
thoroughly).
The switch is on terminals D1 and D2
PHOTOCELLS
The control unit has a 24VAC power supply for photocells with
switch normally closed, and can perform an operational test
before starting the roller shutter opening procedure.
The photocell can be used with two settings:
1. Photocell always active:
Intervention of the photocell during opening or closing causes the
roller shutter to stop.
When the photocell restores, the roller shutter re-opens
completely.