2. Photocell NOT active during opening:
Intervention of the photocell during opening is ignored.
Intervention of the photocell during closing causes the gate to
re-open completely.
Independently of the setting selected, when the gate is paused
while opening, the time count for any automatic re-closure will
only start after the photocell restores.
• Connect the photocell transmitter power cables between
terminals L10 (GND) and L11 (+) on the control unit.
• Connect the photocell receiver power cables between terminals
L10 (GND) and L9 (+) on the control unit.
• Connect the photocell receiver output between terminals L6
and L8 on the control unit.
SAFETY EDGES
The control unit has an input for controlling safety edges; this
input is capable of controlling standard edges with switch
normally closed and conductive rubber edges with nominal
resistance of 8.2 kOhms.
Edges can be used with two settings:
1. Edge always active:
Intervention of the photocell during opening or closing causes the
roller shutter to stop.
2. Edge NOT active during opening:
Intervention of the edge during opening is ignored.
Intervention of the edge during closing causes the roller shutter
re-open completely.
m
NOTE: Independently of the settings selected, any
subsequent automatic
re-closure will be cancelled.
Standard edge with switch normally closed: connect the edge
cables between terminals L7 and L8 on the control unit.
In order to satisfy the requirements of standard EN12978, it
is necessary to install safety edges with a control unit which
constantly monitors correct operation. If control units are used
with the option of running tests by means of interrupting the
power supply, connect the control unit power supply cables
between terminals L10 (GND) and L11 (+).
Conductive rubber edge: connect the edge cables between
terminals L7 and L8 on the control unit.
m
PLEASE NOTE: operational testing on edges is reserved
for optical edges and standard edges (only if equipped with
suitable control units).
DO NOT enable testing if conductive rubber edges are used
or standard edges used without a suitable control unit for
controlling function.
m
NOTE: use the special interface (code 35A024) for
connection of the optical bars, de-activating the operational
test on the bars
START INPUTS
The START1 and START2 inputs are factory set for connection
to devices with normally open (NO) contacts. Their operation
depends on the operating mode set on dipswitches 1, 2, 3, 4, 5,
and 6.
1. DEAD MAN function (Dip 1 ON)
The user opens (START1) and closes (START2) maintaining this
command active.
m
WARNING: The settings of Dips 2, 4, 5, and 6 are
ignored
Dip1 ON
DEAD MAN function enabled
CLOCK Function disabled regardless of the
Dip2
position of Dip 2
Individual Controls: START1 opens, START2 closes
ON
(Up-Down)
Dip3
Unified Controls: START1 opens and closes
OFF
(Start-Stop) START2 disabled
Automatic closure disabled regardless of the
Dip4
position of Dip 4
Condominium logic disabled regardless of the
Dip5
position of Dip 5
Inversion mode disabled regardless of the
Dip6
position of Dip 6
WARNING: with the DEAD MAN function on, the intervention
of the photocell or of the safety edge during the closure phase
always makes the rolling shutter to stop.
2. CLOCK Function (Dip 2 ON)
m
WARNING: Set Dip 1 to OFF
START1 Input: Normal impulse input, able to manage opening and
closing, even if the CLOCK function is active.
START2 Input: Timer input. When the START2 input is activated,
the shutter opens and closes automatically only after the input is
deactivated.
If automatic closure is activated (Dip 4 ON), when the timer is
deactivated the shutter does not close immediately; it closes after
the set pause time.
Dip1 OFF
The DEAD MAN function must be disabled
Dip2 ON
Clock Function enabled
START1 and START2 have different functions
Dip3
regardless of the position of Dip 3
When the START2 input is released, the pause
ON
time countdown starts, after which the shutter
closes
Dip4
When the START2 input is released, the shutter
OFF
closes immediately
The START1 input impulse is not accepted when
ON
opening (Condominium Logic)
Dip5
The START1 input impulse is accepted even when
OFF
opening
The input impulse on opening/closure causes
ON
direction change
Dip6
The input impulse on opening/closure causes
OFF
stop (Step-Step Logic)
- 12 -