Installing the SHLX
1/4" per Foot
Downward Slope
WARNING: Use UL approved Category III vent material only. No other vent material is
permitted. Owner must refer to vent manufacturer's instructions and specifications. Venting
information can be found at www.Eccotemp.com.
CAUTION: Follow the vent manufacturer's installation instructions as design might vary fom
manufacturer to manufacturer.
COMPONENTS FOR LOW TEMPERATURE OPERATION
In Canada, all components and/or controls affecting the safety of the appliance shall be individually
certified for the lower ambient operating temperature of the outdoor appliance, or enclosed in a
supplementary heated compartment.
All operating components and or controls not affecting the safety of the appliance will be reviewed
for their acceptance in the particular application, bearing in mind their certified temperature
limitations and the affect that any malfunction may produce.
The heated compartment shall not rely solely on recirculating air for supplementary heat. It is not
advised to operate the water heater if the ambient temperature is at or below 32°F/0°C to prevent
damage to the water heater, to property, or to people.
PLEASE NOTE: SHLX IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECT TO
Support: Support.Eccotemp.com
Insulation
Material
Vent Pipe
Ceiling Board
Inspection
Hole #1
CHANGE WITHOUT NOTICE. PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.