10.2
Air filter
The air filter should be cleaned regularly removing dust and dirt to avoid:
Carburettor malfunction.
Starting problems.
Reduced engine power.
Unnecessary wear to engine parts.
Abnormal fuel consumption.
Cleaning the air filter:
Dismantle the air filter cover and remove the air filter.
Wash in clean, warm soapy water.
Ensure that the filter is dry before refitting.
An air filter used for a long period of time can never be cleaned completely. Therefore it
is necessary to replace the air filter from time to time with a new filter.
Attention! Do not ever use the unit without its air filter. The filter must be kept
clean. A damaged filter must be replaced with a new one.
10.3
Change/adjustment of the spark plug
Attention! Worn-out spark plugs or too large distance between breaker
contacts decrease the engine performance.
Turn the unit off.
Disconnect the sparkplug cable from the spark plug.
Unscrew counterclockwise the spark plug with a spark plug key. Do not use any other
tool in order to prevent any damage.
Use a control template (available at specialized shops) and check the distance between
the breaker contacts. The distance must be 0.635 mm.
If necessary, correct the distance by carefully bending the ignition arch of the spark plug.
Clean the spark plug with a wire brush.
Insert a cleaned and adjusted spark plug or replace the damaged one by a new one.
Reconnect the spark plug cable.
10.4
Carburettor adjustment
The carburettor was adjusted to optimum performance already during production. If the
carburettor requires readjustment, have it done at a specialized expert repair shop.