Operating instructions
3
Transport and storage
3.1
Inspect condition on delivery
Inspect the valve for damage upon receipt.
In case of transport damage, determine and document the precise extent of the damage, and report it
immediately to the supplying dealer/carrier and the insurer.
3.2
Transportation
Transport the valve in the packaging supplied.
The valve is delivered ready to operate with body ends protected by cover caps.
Protect the valve against hammering, impacts, vibrations and dirt.
Adhere to a transport temperature range of –20 °C to +65 °C.
3.3
Storage
Store the valve in a clean and dry place.
In damp storage rooms, use desiccants or heating to prevent the formation of condensation.
Storage at a temperature range of –20 °C to +65 °C.
4
Description of the globe valve
Refer to the respective catalogue page for further detailed information.
4.1
Structure
Design
Non-automatically opening and closing, straight-type globe valve.
Component
Body
Bonnet
Operating mechanism
Obturator
Stem bushing
Body end
4.2
Marking
The valves are provided with an individual marking for identification.
Symbol
DN ...
PN ...
- ... °C +... °C
01/18
12345
01234567
EN 1626
0045
0045
e.g. CF8 / 1.4308
22
Design
Straight-type
Flanged, internal stem thread,
Flanged, without stem thread
Rising stem
Disc with seal made of non-metallic materials
Non self-sealing, packing gland
with soldering end
with welding end
with threaded end (G; R; NPT)
with flanged connection
with welded-in/soldered-in pipes
Explanation
Nominal diameter
Rated working pressure
Temperature, min. / max.
Manufacturer's mark "HEROSE"
Year of construction MM/YY
Type
Serial no.
Product standard
CE-mark and number of the notified body
PI-mark and number of the notified body
Material
Phone +49 4531 509-0