Operating instructions
7
Maintenance and service
7.1
Safety during cleaning
Take note of the specifications in the safety data sheet, the general occupational health and safety rules
and the HEROSE information sheet "Use with oxygen" if degreasers are used for process-related reasons
for the cleaning of bearing parts, unions and other precision parts.
7.2
Maintenance
The maintenance and inspection intervals must be defined by the operating company according to the
operating conditions and the national regulations.
The manufacturer's general recommendations for the maintenance and inspection of the valve are given
in the table below and are based on the national standards of the country of manufacture.
Test and maintenance intervals
Description
Inspection
Functional testing
External inspection
Internal inspection
Hydraulic test
Recommended intervals
Interval
During start-up
Inspection and maintenance in ac-
cordance with the respective legal
regulations.
In Germany, for example,
according to the Operational Safety
Ordinance
Inspection and maintenance in ac-
cordance with the respective legal
regulations.
In Germany, for example,
according to the Operational Safety
Ordinance
every 5 years or ≥ 500 loading
cycles
10 years
herose.com
Scope
Visual inspection
of the valve for damage
of the marking for legibility
Installation position
Leak-tightness
at the packing gland
between bonnet and body
of the valve seat
Test the opening and closing
functions of the valve.
Test the opening and closing
functions of the valve including
a visual inspection.
Function and tightness test
including visual inspection.
Replacement of all sealing
elements, including a function
and tightness test as well as a
visual inspection.
Replacement of all sealing
elements, including a function, leak
and pressure test as well as an in-
spection.
33