Operating instructions
7.4
Fault table
Fault
Leak at the stem
Leak between cover
and body
Leak in the seating
Body leaking
Valve does not open /
close
7.5
Spare parts
We require the following details for your spare part orders:
 article no. of the spare part package,
 desired delivery quantity,
 dispatch and delivery address,
 desired method of dispatch.
7.6
Returns / complaints
Use the Service form in case of returns/complaints.
Cause
Gland nut loose
Packing gland defective
Fit on the stem damaged
Bonnet loose
Seal damaged
Foreign bodies between
obturator and seating
Seating damaged
Seal of obturator damaged
Discontinuity/gas cavity open
Gland nut overtightened
Thread seized
Actuator not working
Contact in case of service:
Herose.com  Service  Complaints
E-mail:
service@herose.com
Fax:
+49 4531 509 – 9285
herose.com
Remedy
 Retighten the gland nut
 Replace the packing gland
 Replace the stem
 Tighten the bolts to the specified
torque
 Replace seal
 Remove foreign body / flush the
system
 Replace the body
 Replace the obturator
 Replace the body
 Loosen the gland nut
 Tightness must still be ensured
 Replace bonnet
 Check energy supply to the
actuator
 Check limit switches
35