Insert ignition cycle
Pressing button 4 (ON/OFF) for a few seconds allows to start the insert ignition cycle. After a few seconds the display shows "Fun ASP", the flue gas intake
device switches on and, after 10 seconds, the ignition resistance switches on along with the motor reducer that loads the pellets. In this phase, "LoAd
PELL" appears, divided into two sub-phases: pre-load and successive "LoAd PELL" phase. The pre-load phase has duration of about 3 minutes, after
which the insert passes to the successive "LoAd PELL" phase. After about 8 minutes, with the flame on, the board displays "FirE on" and remains in this
phase for about 5 minutes in order to allow the fire to expand uniformly along the entire brazier. After these phases, which have complete duration of
maximum 18 minutes, the insert goes into work mode at the pre-set power.
It is recommended to make the insert function at power 3 for a few minutes before passing to maximum power.
In the case of no pellet ignition, the insert goes into alarm conditions (ALARM no FirE).
The alarm may occur also if the brazier is dirty; in this case, clean the brazier and re-start the insert.
Insert working mode
During normal insert functioning, the upper display will show the power set (Po 1, Po 2, Po 3, Po 4, Po 5), while the lower display shows the temperature
SET. The work power can be modified by the user via buttons 5 and 6. During this phase the insert works at the power set if the temperature in the
boiler is below the SET temperature. The insert starts to modulate by lowering the supply of pellets and reducing the fumes intake speed on reaching the
temperature set by the SET temperature lowered by 5 degrees.
Example: SET temperature set at 75°C.
Work power set at 5.
On reaching 71°C in the boiler, the power is automatically taken to 4.
On reaching 72°C in the boiler, the power is automatically taken to 3.
On reaching 73°C in the boiler, the power is automatically taken to 2.
On reaching 74°C in the boiler, the power is automatically taken to 1.
On reaching 75°C in the boiler, the insert goes into "Eco H2o" (functioning economy).
The insert switches off automatically if it remains in functioning economy for more than 2 hours (Pr23) or if it exceeds the temperature set on "Set H2o" by
10°C (Pr12).
Any room thermostat connected o the insert will act on the functioning of the same, sending it into functioning economy mode (the display shows "Eco
toFF"). It is however fundamental, that the room thermostat does not close any system zone valves, because when excess heat occurs due to the inertia of
the insert, this will be disposed of by starting the pump until the boiler temperature goes back to normal temperature. In the case of a black out, if the
interruption of the current is less than 20", on return of the electric energy, the insert re-starts at the working power that it had previously, otherwise the
display shows the "StoP FirE" anomaly status. The intake will be increased to maximum in order to expel residual flue gas. When the insert has cooled, the
ignition phase is re-started.
If key 1 is pressed during functioning, the upper display shows the temperature of the outlet flue gas. The brazier cleaning cycle is performed at pre-
established intervals of time (indicated in the display with "CooL FirE") for a duration which is also established.
Insert switch-off
Pressing button 4 (ON/OFF) switches the insert off. The upper display will show "OFF". The flow of pellets is interrupted, switching the motor reducer off. The
flue gas intake device speed is increased to maximum and is switched off after about 10 minutes.
Modifying set temperature
The value of the maximum temperature in the boiler can be varied at any time by the user. To modify it enter in SET temperature by pressing button 3 (SET
and then with buttons 1 and 2 select the desired value (do this when the insert works at a power from 1 to 5).
Chrono-thermostat
PARAMETER
UT01
Sets the current day and method of use
UT02
Sets the current time
UT03
Sets minutes
UT04
Sets technical parameters (RESERVED)
UT05
Sets PROGRAM 1 switch-on time
UT06
Sets PROGRAM 1 switch-off time
UT07
Choice of days with insert ignition
UT08
Sets PROGRAM 2 switch-on time
UT09
Sets PROGRAM 2 switch-off time
UT10
Choice of days with insert ignition
UT11
Sets PROGRAM 3 switch-on time
UT12
Sets PROGRAM 3 switch-off time
UT13
Choice of days with insert ignition
UT14
Sets PROGRAM 4 switch-on time
UT15
Sets PROGRAM 4 switch-off time
UT16
Choice of days with insert ignition
The chrono-thermostat function allows to program automatic switch-on/off of the insert throughout the week.
Press button 3 twice to enter programming. Press button 3 again to scroll all of the programming parameters explained below. Pressing key 4 allows to exit
programming ay any time.
DESCRIPTION
13
VALUE THAT CAN BE SET
OFF, Lun, Mar, Mer, ..., Dom
From 00 to 23
From 00 to 59
From 00 to P5
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Lun to Dom
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Lun to Dom
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Lun to Dom
From 00:00 to 23:50 in 10' steps
From 00:00 to 23:50 in 10' steps
Between on/off from Lun to Dom