Signals On The Display; The Suction Motor Does Not Work; Fault Diagnosis - Tornado OB 20/14 Manual De Operaciones Y Mantenimiento

Tabla de contenido

Publicidad

Signals On The Display

A001: Indication of the version of the electronic check card (the last number indi-
cates the revision of the check card).
Pb24: Indication battery check card set for lead batteries.
GE24: Indication battery check card set for gel batteries.
---- (blinking): signal indicating the discharged batteries

The Suction Motor Does Not Work

1. Verify that the key switch (8) is in the correct position.
2. Check the charge level of the batteries.
3. Check that the battery connector is correctly plugged in.
4. Verify that the switch (6) is on.
5. Check that the red connector of the suction motor (1) is correctly plugged in.
If the problem persists, please contact the authorized technical assistance.