Descargar Imprimir esta página

PYD Electrobombas 3TSS Manual De Instalación Y Mantenimiento página 22

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING AND MAINTENANCE MANUAL
SOLAR PUMPING KIT
SELECTION OF PANELS FOR SINGLE PUMPS
SOLAR POWER
PUMP POWER (W)
REQUIRED (W)
80
120
210
500
600
750
1.000
(helical pump)
1.000
(centrifugal pump)
1.500
2.200
3.000
www.proindecsa.com / proindecsa@proindecsa.com
(RECOMMENDED)
COMPOSITION OF
THE SOLAR INSTA -
LLATION
110
110W*1
160
80W*2
270
90W*3
680
85W*8
800
100W*8
1.050
75W*14
1.400
100W*14
1.600
100W*16
2.300
230W*10
3.300
250W*14
4.500
250W*18
VMP PEAK VOLTA -
OPEN CIRCUIT VOL -
GE (V)
TAGE VOC (V)
17-18
17-18
17-18
17-18
17-18
17-18
17-18
17-18
30,5
35
35
22
CONNECTION
BETWEEN SOLAR
PANELS
21-22
2 panels con-
21-22
nected in series
3 panels con-
21-22
nected in series
2 groups in
21-22
parallel of 4
panels in series
2 groups in
21-22
parallel of 4
panels in series
2 groups in
21-22
parallel of 7
panels in series
2 groups in
21-22
parallel of 7
panels in series
2 groups in
21-22
parallel of 8
panels in series
2 groups in
36,8
parallel of 5
panels in series
2 groups in
43
parallel of 7
panels in series
2 groups in
43
parallel of 9
panels in series

Publicidad

loading