Run capacitor replacement VLS204 to 404A AC
The run capasitor is placed in the left side
of the compressor compartment, fixed to
the terminal bracket.
2. Loosen the nut from the assembly plate
by using a wrench M13.
4. Exchange the wires 1/1 from the old
capasitor to the new one
1. Remove nuts to unmount assembly plate
for run capacitor. Lift up and pull out the
assembly plate.
3. Unmount the 2 wires by using a nose
plier.
5. When remounting assembly plate re-
member remounting of earth wires.
35
GB